中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTKCT-0.66
KCT-0.66 Indoor Low Voltage Split-core Current Transformer 0.66kV Open Type
0.66kVKCT-0.66
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A (0.2S/0.5S/0.5/1.0)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:KCT-0.66

KCT-0.66 Indoor Low Voltage Split-core Current Transformer 0.66kV Open Type

Indoor low voltage split-core open type current transformer, 0.66kV rated, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Split-core design, can be directly installed on existing busbars without power interruption. Easy installation, wide range of current ratios available. Customizable ratios and specifications.

Key Engineering Advantages

  • LV split-core current transformer
  • 0.66kV
  • open type
  • no power outage needed for installation
  • easy mounting
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: KCT-0.66

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A
Metering & Protection Class:0.2S/0.5S/0.5/1.0
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

KCT-0.66 is a low-voltage split-core current transformer for indoor use, enabling installation without power interruption. Suitable for current measurement and protection in LV distribution systems.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeKCT-0.66Factory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5ARatio check at rated frequency
Accuracy Class0.2S/0.5S/0.5/1.0Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low-voltage (0.66kV) distribution panels
  • Retrofitting existing busbars without de-energizing
  • Current measurement for metering or monitoring
  • Protection applications in LV networks

Not Recommended For

  • Outdoor or high-voltage (above 1kV) applications
  • High-accuracy revenue metering (accuracy class 0.2S is borderline, but not for fiscal metering)
  • DC current measurement
  • High-temperature or corrosive environments without additional protection

Topology & Wiring

Connect primary conductor through the window. Secondary terminals are 1S1 and 1S2 (for protection winding, 2S1-2S2 if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / GB/T 20840 for installation.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: Can this CT be installed without power outage?

A: Yes, the split-core design allows installation on existing busbars without de-energizing the circuit.

Q: What accuracy classes are available?

A: Accuracy classes include 0.2S, 0.5S, 0.5, and 1.0, suitable for various metering and protection needs.

Q: What is the rated secondary current?

A: The secondary current is 5A, as specified.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

KCT-0.66
10 cols · 56 rows

KCT SeriesOpen-Type Current Transformer — Technical Data

ModelRated current ratioburden (VA) cosφ=0.8
0.20.20.50.50.80.811
KCT-23100/5————1.5—1—
KCT-23200/5————1.5—1—
KCT-23400/5————2.5—2—
KCT-23500/5————2.5—2—
KCT-58300/1————5—5—
KCT-58500/1————5—5—
KCT-581000/15———15—15—
KCT-58200/55———5—5—
KCT-58400/55———5—5—
KCT-58500/5————10—10—
KCT-581000/5————20—20—
KCT-410500/15———10—10—
KCT-4101000/110———25—25—
KCT-4101500/115———25—25—
KCT-410500/5————10—10—
KCT-4101000/5————25—25—
KCT-4101500/5————25—25—
KCT-610600/1————5—5—
KCT-6101000/1————10—10—
KCT-6101500/1————20—20—
KCT-610600/5————5—5—
KCT-6101000/5————10—10—
KCT-6101500/5————20—20—
KCT-8101000/110———20—20—
KCT-8101500/120———30—30—
KCT-8102000/130———40—40—
KCT-8101000/5————20—20—
KCT-8101500/5————30—30—
KCT-8102000/5————40—40—
KCT-23300/5————2.5—2—
KCT-23400/5————2.5—2—
KCT-23500/5————2.5—2—
KCT-58200/5————2.5—2.5—
KCT-58500/5————5—5—
KCT-581000/5————10—10—
KCT-582000/5————20—20—
KCT-410500/5————10—10—
KCT-4101000/5————20—20—
KCT-4101500/5————25—25—
KCT-4102000/5————25—25—
KCT-610600/5————5—5—
KCT-6101000/5————10—10—
KCT-6101500/5————20—20—
KCT-6102000/5————30—30—
KCT-8101000/5————20—20—
KCT-8101500/5————30—30—
KCT-8102000/5————40—40—
KCT-10101500/5————30—30—
KCT-10102000/5————40—40—
KCT-10103000/5————50—50—
KCT-12101500/5————30—30—
KCT-12102000/5————40—40—
KCT-12103000/5————50—50—
KCT-16101500/5————40—40—
KCT-16102000/5————50—50—
KCT-16103000/5————60—60—
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of KCT-0.66 — click image to zoom / view original.

Product Overview

About This Product

KCT-0.66

The KCT-0.66 is an indoor, low-voltage split-core current transformer built to the IEC 61869 and GB/T 20840 standard family, rated 0.66kV with a 5A secondary and intended for current measurement in low-voltage distribution circuits at 50/60Hz. It is an open-type unit whose split core allows it to be placed around existing conductors.

Insulation is dry epoxy resin, giving a solid cast body around the core and windings. Accuracy classes 0.2S, 0.5S, 0.5 and 1.0 are offered, so metering and general measurement duties can be matched to the required class; rated burden in VA is stated on the nameplate and datasheet. The split-core format means installation does not require a power outage, which suits retrofits and live LV boards.

It is intended for indoor service only and must not be installed in outdoor or exposed locations. Secondary terminals must never be open-circuited while the primary is energized. Before commissioning, verify polarity, ratio and insulation resistance, and earth the secondary at one point per the terminal diagram. Custom ratios and accuracy classes are available; request the document package and lead time with your enquiry. [On Request] for weight and dimensions.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs