Outdoor split-core current transformer, 10kV, model KXLW-10G. Install directly on cables or conductors without cutting. Hot-line installation possible with HV cables. Outdoor resin casting, UV resistant, -40°C to +40°C. With open-circuit protection, creepage >500mm. Compliant with IEC 61869 and GB/T 20840 standards.
KXLW-10G is a 10kV outdoor split-core current transformer for metering and protection, suitable for hot-line installation on cables or conductors.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | KXLW-10G | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -40°C ~ +40°C | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary conductor through the split-core. Secondary terminals: 1S1 and 1S2 for metering winding; if dual-winding, protection winding uses 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 and GB/T 20840.2 terminal markings.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of KXLW-10G?
A: The insulation level is 12/42/75kV, meaning 12kV maximum system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: Can KXLW-10G be installed on live cables?
A: Yes, it is designed for hot-line installation on HV cables without cutting, thanks to its split-core design.
Q: What standards does KXLW-10G comply with?
A: It complies with IEC 61869 and GB/T 20840 standards.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 |
| Rated insulation level | 12/42/75kV |
| Rated frequency | 50Hz or 60Hz |
| Ambient temperature | -40℃~+40℃ |
| Altitude | Not exceeding 3000 m |
| Rated primary current | 100~600A |
| Rated secondary current | 5A or 1A |
| Rated output | 2.5~5VA (with 2×2.5mm² cable10 m) |
| Creepage distance | >500mm |
| with open-circuit protection | — |
Dimension & outline drawing of KXLW-10G — click image to zoom / view original.
In a 10kV outdoor distribution bay, pole-mounted enclosure or compact substation, this unit is the current transformer that steps primary current down to a metering or protection level. It is a dry epoxy resin cast, split-core CT rated 10kV with a 12/42/75kV insulation level, built for hot-line installation on existing conductors.
Factory routine testing includes ratio and polarity verification, with [On Request] for the full test report package. Primary current spans 100~600A and secondary is 5A or 1A, with rated output 2.5~5VA into a 2×2.5mm² cable of 10 metres. Creepage distance exceeds 500mm. Short-time thermal and dynamic capability data is [On Request]. Unlike fused designs, this unit carries no primary fuse, so protection coordination relies on the upstream scheme.
Compliance follows GB/T20840.1, 2 and IEC61869-1, 2; calibration certificates for trade-settlement metering are [On Request]. The UV-resistant housing suits outdoor lines and box substations from -40°C to +40°C at altitudes up to 3000m. Earth the secondary at one point and never open-circuit it while energized. DC or non-standard frequencies are not applicable. Custom ratios, classes and winding configurations are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.