LDFC-10 Indoor Foot-Fixed High-Precision Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),100VA(3P). Design: Dry Epoxy Resin, 50Hz/60Hz operation.
Indoor 10kV ring main unit current transformer with high precision (0.2/0.5/3P) and dry epoxy insulation, suitable for metering and protection.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LDFC-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/3P(6P) | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 30VA(0.2),40VA(0.5),100VA(3P) | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50Hz/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1-1S2 for metering (0.2/0.5), 2S1-2S2 for protection (3P). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the accuracy class of this CT?
A: It has accuracy classes 0.2, 0.5, and 3P (6P) for metering and protection.
Q: What is the rated burden?
A: Rated burden is 30VA for 0.2 class, 40VA for 0.5 class, and 100VA for 3P class.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor use in ring main units.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 |
| Rated insulation level | 0.72/3kV |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Ambient temperature | -5℃~+40℃ |
Dimension & outline drawing of LDFC-10 — click image to zoom / view original.
The LDFC-10 is a 10kV indoor current transformer that uses dry epoxy resin insulation, a construction that removes the need for an oil or gas medium and keeps the unit compact for panel mounting. Its secondary winding is available with metering and protection outputs, with accuracy classes of 0.2, 0.5, and 3P(6P) and rated burdens of 30VA, 40VA, and 100VA respectively, at 50Hz or 60Hz. The rated secondary current is 5A or 1A, and the rated insulation level is 0.72/3kV.
This square foot-fixed unit is intended for indoor service in 10kV ring main cabinets and similar switchgear, where its resin-cast body suits the restricted space and controlled environment. It is not intended for outdoor installation or for use above its 10kV class. The secondary must never be open-circuited while the primary is energized; before commissioning, check insulation resistance, polarity, and ratio, and earth the secondary at one point.
Performance follows GB/T20840.1 and 2 and IEC61869-1 and 2, with test and document packages available [On Request]. The ambient temperature range is -5℃~+40℃. Ratio and accuracy-class options, export packing, and after-sales support are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.