LDJ1-35 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
LDJ1-35 is a 35kV indoor epoxy resin cast current transformer, suitable for medium voltage switchgear applications requiring accurate current measurement and protection.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LDJ1-35 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 40.5/95/185kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary in series with the line. Secondary terminals: 1S1/1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure shorting and grounding before disconnecting secondary wiring.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of LDJ1-35?
A: The insulation level is 40.5kV system; power-frequency withstand 95kV; lightning impulse withstand 185kV peak.
Q: What are the available secondary currents?
A: Secondary current options are 5A or 1A.
Q: What accuracy classes are available?
A: Accuracy classes include 0.2S, 0.2, 0.5, and 10P10 with various rated outputs.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA)COSφ=0.8 | Rated secondary current | Short-time thermal current I1th (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|
| 30-300 | 0.5/10P | 15 15 20 30 20/20 | 5A or 1A | 150 I1n | 375 I1n | 70 |
| 400 | 0.5/10P | 15 15 20 40 20/20 | 5A or 1A | 63 | 130 | 70 |
| 500 | 0.2/10P | 15 15 20 40 25/25 | 5A or 1A | 63 | 130 | 70 |
| 600-800 | 0.25/10P | 20 20 30 50 30/30 | 5A or 1A | 63 | 130 | 70 |
| 1000-1200 | 0.2/5 | 20 20 30 50 40/40 | 5A or 1A | 63 | 130 | 70 |
| 1500 | 10P/10P | 20 30 50 50 40/40 | 5A or 1A | 80 | 160 | 70 |
| 2000 | — | 20 30 50 50 50/50 | 5A or 1A | 80 | 160 | 70 |
Dimension & outline drawing of LDJ1-35 — click image to zoom / view original.
The LDJ1-35 is a 35kV indoor single-phase epoxy resin cast current transformer, used to step primary current down to a 5A or 1A secondary for metering and protection in medium-voltage switchgear. Its dry epoxy body is produced by vacuum casting or automatic pressure gelation, giving a solid, void-free insulation system rather than an oil or gas dielectric.
The unit is available across a wide primary current range, with accuracy class combinations spanning 0.2, 0.25, 0.5 and 10P and rated outputs from 15VA to 50VA depending on the ratio ordered; short-time thermal and dynamic ratings scale with the primary current, and the mass is 70kg. Insulation is rated 40.5/95/185kV at 50/60Hz. Standard catalogue ratios suit routine projects, while non-standard ratios and accuracy combinations are quoted to order.
It is intended for indoor installation in heavy-industry distribution — metallurgy, mining, cement and chemical plants — and is commissioned with insulation resistance, polarity and ratio checks. The secondary must never be open-circuited while the primary is energized. Calibration certificates and routine test documentation are available [On Request], and export packing and after-sales support are arranged at quotation.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.