LDZB7-35 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor 35kV class current transformer for medium-voltage switchgear, suitable for metering and protection up to 40.5kV systems.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LDZB7-35 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 40.5/95/185kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The rated insulation level is 40.5/95/185kV, meaning 40.5kV system voltage, 95kV power-frequency withstand, and 185kV lightning impulse withstand.
Q: What accuracy classes are available?
A: Optional accuracy classes include 0.2S/0.5S for metering and 5P10/5P20 for protection, with rated outputs from 10-30VA.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only. Outdoor installation would require additional weatherproofing.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | 0.2(S)/0.5(S) | 0.5 | 5P10 | 5P20 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| 300 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 10 | 15 | 15 | 10 | 31.5 | 80 | 91 |
| 400 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 10 | 15 | 20 | 15 | 45 | 112.5 | 91 |
| 500 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 20 | 25 | 15 | 20 | 53 | 130 | 91 |
| 600 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 30 | 30 | 30 | 30 | 80 | 160 | 91 |
| 800 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 30 | 30 | 30 | 30 | 80 | 160 | 91 |
| 1000-1200 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 30 | 30 | 30 | 30 | 100 | 160 | 91 |
| 1500-3150 | 0.2(S)/0.5(S)/5P/5P 0.2(S)/5P/5P/5P 0.5(S)/5P/5P/5P | 30 | 30 | 30 | 30 | 100 | 160 | 91 |
Dimension & outline drawing of LDZB7-35 — click image to zoom / view original.
The LDZB7-35 is a 35 kV indoor single-phase epoxy resin cast current transformer, typically installed in switchgear bays and ring-main units to step primary current down to 5A/1A for metering and protection. Its dry epoxy resin body insulates the primary and secondary windings, and each unit is routine-tested at the factory for ratio and polarity before dispatch, with test records available [On Request].
The rated output window and accuracy class combinations are confirmed on the nameplate and official datasheet, allowing the secondary burden to be matched to the connected relays and meters. The insulation level is 40.5/95/185kV at 50/60Hz, and the ambient range is -5℃~+40℃. Compliance follows the GB/T 20840 series, with type and routine test documentation supplied as part of the delivery package.
This unit is for indoor service only and must not be installed in outdoor exposed locations. Primary connections follow the P1/P2 markings, with the secondary earthed at one point; the secondary must never be open-circuited while energized. OEM and private-label options, customized ratios and accuracy classes, and the routine test report package are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.