LDZJ9-20 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 5A/1A. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor 10kV current transformer for medium-voltage switchgear, suitable for metering and protection up to 20kV systems.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LDZJ9-20 | Factory nameplate marking |
| Primary Voltage | 20kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 24/65/125kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window. Secondary terminals: 1S1 and 1S2 for metering, 2S1 and 2S2 for protection if applicable. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: What secondary currents are available?
A: Secondary current is 5A or 1A as per specification.
Q: Is this CT suitable for outdoor use?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I 1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 0.2 (S) | Accuracy class & rated output (VA) COSφ=0.8 0.5 (S) | Accuracy class & rated output (VA) COSφ=0.8 5P10 | Accuracy class & rated output (VA) COSφ=0.8 5P15 | Accuracy class & rated output (VA) COSφ=0.8 5P20 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) Weight |
|---|---|---|---|---|---|---|---|---|---|
| 300-400 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 20 | 15 | 10 | 45 | 112.5 | 48 |
| 500-600 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 30 | 15 | 20 | 63 | 130 | 48 |
| 700-800 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P 0.5(S)/5P | 15 | 20 | 40 | 30 | 25 | 63 | 130 | 48 |
| 1000 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P 0.5(S)/5P | 20 | 30 | 50 | 40 | 30 | 80 | 160 | 48 |
| 1200-1250 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P 0.5(S)/5P | 20 | 30 | 50 | 40 | 30 | 80 | 160 | 48 |
| 1500-2000 | 0.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P 0.5(S)/5P | 20 | 30 | 50 | 40 | 30 | 100 | 160 | 48 |
Dimension & outline drawing of LDZJ9-20 — click image to zoom / view original.
The LDZJ9-20 is a 20 kV indoor single-phase current transformer built on a dry epoxy resin casting system, so the insulation is solid rather than oil- or gas-based and the unit needs no oil handling or gas supervision in service. Its compact cast body suits through-wall mounting in switchgear compartments where panel space is tight.
Accuracy classes 0.2(S), 0.5(S) and 5P are available with rated outputs from 10 VA to 50 VA depending on the primary current selected; short-time thermal current reaches 45 kA for 1 s at the lower primary ratings and rated dynamic current up to 160 kA. Compared with oil-immersed or SF6 designs, the dry casting removes fluid maintenance but fixes the insulation inside the mould. Type and routine test reports are available [On Request].
Typical deployment is indoor metering and protection in substation bays and busbar sections, at 50/60 Hz and ambient -5℃~+40℃. Before energising, verify the secondary burden against the rated VA, earth the secondary at one point and confirm polarity; the secondary must never be open-circuited while energised. Ratios and class combinations are configurable, with documents and delivery quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.