LFS-10G Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 10VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor 10kV epoxy cast current transformer for medium-voltage switchgear, suitable for metering and protection with 0.2S/0.5S accuracy.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LFS-10G | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 10VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformer: connect primary terminals in series with the line. Secondary terminals: 1S1/1S2 for metering winding (0.2S/0.5S), 2S1/2S2 for protection winding (10P). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: Can the secondary current be 1A?
A: Yes, the secondary current can be 5A or 1A as per the description.
Q: What are the accuracy classes available?
A: Accuracy combinations include 0.2S/10P and 0.5S/10P, with rated outputs as specified.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 0.2 (S) | Accuracy class & rated output (VA) COSφ=0.8 0.5 (S) | Accuracy class & rated output (VA) COSφ=0.8 10P10 | Accuracy class & rated output (VA) COSφ=0.8 10P15 | Short-time thermal current I1th (kA/S) | Rated dynamic current I dyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| 20-200 | 0.2(S)/10P | 10 | 10 | 15 | 10 | 80/1n | 200/1n | 16 |
| 300 | 0.2(S)/10P | 10 | 10 | 15 | 10 | 21 | 50 | 16 |
| 400 | 0.2(S)/10P | 10 | 10 | 15 | 10 | 24 | 60 | 16 |
| 500-600 | 0.5(S)/10P | 10 | 10 | 15 | 10 | 30 | 72 | 16 |
| 800 | 0.5(S)/10P | 10 | 10 | 15 | 10 | 40 | 80 | 16 |
| 1000 | 0.5(S)/10P | 10 | 10 | 15 | 10 | 50 | 80 | 16 |
Dimension & outline drawing of LFS-10G — click image to zoom / view original.
The LFS-10G is a 10 kV indoor single-phase epoxy resin cast current transformer, used for metering and protection on 50/60 Hz systems where the accuracy class directly affects billing and relay coordination. Its dry epoxy body insulates the primary and secondary windings, and the compact dual-body structure keeps the unit at 16 kg for panel mounting.
Accuracy classes 0.2S/0.5S are available with a rated burden of 10 VA, and the parameter table lists 10 VA at 0.2(S) and 0.5(S), 15 VA at 10P10 and 10 VA at 10P15, with short-time thermal current from 80/1n kA/S and dynamic current from 200/1n kA. This places it as an indoor alternative to outdoor cast units, suited to switchgear and metering cabinets where environmental exposure is controlled. Datasheets, outline drawings and type test reports are available [On Request].
Typical deployment includes renewable energy collection and storage step-up stations. Observe primary polarity P1/P2 and secondary polarity, earth the secondary at one point, and never open-circuit the secondary while energized. Harmonic or non-sinusoidal loads require derating; verify the nameplate before installation.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LFS8-10 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 10VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.