KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLFZ1D
LFZ1D Indoor Low Voltage Current Transformer 0.66kV State Grid Standard
0.66kVLFZ1D
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A (0.2S)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LFZ1D

LFZ1D Indoor Low Voltage Current Transformer 0.66kV State Grid Standard

Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, State Grid standard, for high precision current measurement in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. High accuracy class 0.2S, reliable performance. Compact size, easy installation, suitable for metering applications. Customizable ratios and specifications.

Key Engineering Advantages

  • LV current transformer
  • 0.66kV
  • State Grid standard
  • 0.2S high accuracy
  • epoxy resin
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LFZ1D

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A
Metering & Protection Class:0.2S
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LFZ1D is a 0.66kV indoor current transformer with 0.2S accuracy, ideal for high-precision metering in low-voltage distribution. It is not suitable for outdoor or high-voltage applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeLFZ1DFactory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5ARatio check at rated frequency
Accuracy Class0.2SAccuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low-voltage metering (0.66kV)
  • High-accuracy revenue billing (0.2S)
  • State Grid compliant distribution panels
  • Epoxy resin insulated, maintenance-free installations

Not Recommended For

  • Outdoor installations (indoor type only)
  • High-voltage systems above 1kV
  • Protection applications requiring class 5P/10P
  • Environments with severe vibration or mechanical stress

Topology & Wiring

Connect primary through the window; secondary terminals are 1S1 and 1S2 (if dual-winding, 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal markings.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the accuracy class of LFZ1D?

A: 0.2S, suitable for high-precision metering.

Q: Can LFZ1D be used outdoors?

A: No, it is designed for indoor use only.

Q: What standards does LFZ1D comply with?

A: IEC 61869 and GB/T 20840.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LFZ1D
7 cols · 1 rows

LFZ1D Current Transformer

ModelRated primary current (A)Accuracy classRated output (VA)Short-time thermal current (kA/s)Rated dynamic current (kA)Power factor
LFZ1D-SKX110-600.2S560 I1n150 I1nCOSΦ=0.8
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LFZ1D — click image to zoom / view original.

Product Overview

About This Product

LFZ1D

The LFZ1D is an indoor low-voltage current transformer built to the IEC 61869 and GB/T 20840 framework, rated 0.66kV, stepping primary current down to a 5A secondary for metering and control in distribution boards and State Grid-standard installations. Its dry epoxy resin body provides the dielectric design for this voltage class, with creepage, lightning impulse withstand and partial discharge figures stated on the nameplate and official datasheet [On Request].

Accuracy is 0.2S, with a rated output of 5VA at COSΦ=0.8; the LFZ1D-SKX1 row covers 10-60A primary current, a short-time thermal current of 60 I1n and a rated dynamic current of 150 I1n. Within the family, ratio and accuracy class determine the choice, so confirm the primary current against the actual load rather than defaulting to the highest class. Secondary circuits must never be open-circuited while energized.

Typical deployment is indoor metering in wind, photovoltaic and storage collector substations. Before commissioning, verify the secondary burden in VA against the rated output. Over-specifying accuracy wastes budget. Custom ratios and classes, export packing and after-sales support are available on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs