Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, State Grid standard, for high precision current measurement in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. High accuracy class 0.2S, reliable performance. Compact size, easy installation, suitable for metering applications. Customizable ratios and specifications.
LFZ1D is a 0.66kV indoor current transformer with 0.2S accuracy, ideal for high-precision metering in low-voltage distribution. It is not suitable for outdoor or high-voltage applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LFZ1D | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window; secondary terminals are 1S1 and 1S2 (if dual-winding, 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal markings.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the accuracy class of LFZ1D?
A: 0.2S, suitable for high-precision metering.
Q: Can LFZ1D be used outdoors?
A: No, it is designed for indoor use only.
Q: What standards does LFZ1D comply with?
A: IEC 61869 and GB/T 20840.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current (A) | Accuracy class | Rated output (VA) | Short-time thermal current (kA/s) | Rated dynamic current (kA) | Power factor |
|---|---|---|---|---|---|---|
| LFZ1D-SKX1 | 10-60 | 0.2S | 5 | 60 I1n | 150 I1n | COSΦ=0.8 |
Dimension & outline drawing of LFZ1D — click image to zoom / view original.
The LFZ1D is an indoor low-voltage current transformer built to the IEC 61869 and GB/T 20840 framework, rated 0.66kV, stepping primary current down to a 5A secondary for metering and control in distribution boards and State Grid-standard installations. Its dry epoxy resin body provides the dielectric design for this voltage class, with creepage, lightning impulse withstand and partial discharge figures stated on the nameplate and official datasheet [On Request].
Accuracy is 0.2S, with a rated output of 5VA at COSΦ=0.8; the LFZ1D-SKX1 row covers 10-60A primary current, a short-time thermal current of 60 I1n and a rated dynamic current of 150 I1n. Within the family, ratio and accuracy class determine the choice, so confirm the primary current against the actual load rather than defaulting to the highest class. Secondary circuits must never be open-circuited while energized.
Typical deployment is indoor metering in wind, photovoltaic and storage collector substations. Before commissioning, verify the secondary burden in VA against the rated output. Over-specifying accuracy wastes budget. Custom ratios and classes, export packing and after-sales support are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.