Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:5-150A、200-300A、400-500A、600-1000A、1250-1500A; accuracy combination 0.2S/10P10、0.5/10P10 with rated output:0.2S class 10VA, 0.5 class 10VA, 10P10 class 15VA. Short-time thermal current 150I₁ₙ~80I₁ₙ and rated dynamic current 375I₁ₙ~160I₁ₙ corresponding to different current grades, net weight 21kg, operating ambient temperature -5℃~+40℃.
Indoor 10kV current transformer for MV switchgear, suitable for metering and protection. Confirm primary current and accuracy requirements before ordering.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LFZJ9-10A | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection (if available). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12kV system; power-frequency withstand 42kV; lightning impulse withstand 75kV peak.
Q: What are the available accuracy classes?
A: Accuracy combinations include 0.2S/10P10 and 0.5/10P10, with rated outputs 10VA and 15VA respectively.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only due to its epoxy resin casting and embedded installation structure.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 (0.2 (S)) | Accuracy class & rated output (VA) COSφ=0.8 (0.5) | Accuracy class & rated output (VA) COSφ=0.8 (10P10) | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 5-150 | 0.2(S)/10P10 0.5/10P10 | 10 | 10 | 15 | 150 I1n | 375 I1n | 21 |
| 200-300 | 0.2(S)/10P10 0.5/10P10 | 10 | 10 | 15 | 31.5 | 80 | 21 |
| 400-500 | 0.2(S)/10P10 0.5/10P10 | 10 | 10 | 15 | 45 | 100 | 21 |
| 600-1000 | 0.2(S)/10P10 0.5/10P10 | 10 | 10 | 15 | 63 | 130 | 21 |
| 1250-1500 | 0.2(S)/10P10 0.5/10P10 | 10 | 10 | 15 | 80 | 160 | 21 |
Dimension & outline drawing of LFZJ9-10A — click image to zoom / view original.
This is a 10 kV indoor single-phase current transformer, typically installed in switchgear bays such as KYN28 or ring-main units to step primary current down to 5 A or 1 A for metering and protection. Its dry epoxy resin casting and cylindrical embedded structure keep the footprint compact, helping save panel space and simplify switchroom layout. The 21 kg cast body suits fixed indoor mounting.
The LFZJ9-10A covers primary currents from 5 A to 1500 A with accuracy classes 0.2(S), 0.5 and 10P10, each rated 10 VA or 15 VA at COSφ=0.8, so secondary burden can be matched to the connected relays and meters. Insulation is rated 12/42/75 kV at 50/60 Hz, and short-time thermal and dynamic ratings are stated per current range. Type and routine test reports support verification; other documents are [On Request].
Typical indoor deployments include rail, data-centre, hospital and water-utility distribution rooms. Before energising, check insulation resistance, polarity and ratio. Never open-circuit the secondary while energised. The 10 kV class is an upper limit; do not apply it at higher voltages. Ratio, class and winding configurations are customisable on request.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:5-150A、200-300A、400-500A、600-1000A、1250-1500A; accuracy combination 0.2S/10P10 & 0.5/10P10, rated output:0.2S 10VA, 0.5 10VA, 10P10 15VA. Corresponding short-time thermal current and dynamic stable current vary by current grade, net weight 21kg, ambient operating temperature -5℃~+40℃.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.