KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLFZZB5-10
LFZZB5-10 Indoor Single-phase Epoxy Resin Casting Current Transformer
10kVLFZZB5-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LFZZB5-10

LFZZB5-10 Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current:20-50A、75A、100A、150A、200A、300A; accuracy combinations:0.2S/0.5、0.2S/10P、0.5/10P, rated output:0.2S10VA、0.5 15VA、10P15 20VA、10P20 25VA. Matched short-time thermal current & dynamic stable current for each gear, net weight 35kg, ambient operating temperature -5℃~+40℃.

Key Engineering Advantages

  • 10kV cast-type CT with rectangular structure
  • weight 35kg
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LFZZB5-10

Electrical Parameters

Primary Rated Voltage (Un):10kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 10kV cast-resin current transformer for MV switchgear, metering and protection. Suitable for 50/60Hz systems up to 12kV.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLFZZB5-10Factory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • Revenue metering with 0.2S accuracy
  • Protection schemes with 10P class
  • 10kV distribution networks

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) applications
  • High-voltage transmission systems above 12kV
  • DC systems

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: 12kV system; power-frequency withstand 42kV; lightning impulse withstand 75kV peak.

Q: What accuracy combinations are available?

A: 0.2S/0.5, 0.2S/10P, and 0.5/10P.

Q: Can it be used outdoors?

A: No, it is designed for indoor use only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LFZZB5-10
6 cols · 6 rows

LFZZB5-10 and LMZZB5-10 Current Transformer — Technical Data

Rated primary current (A)Accuracy classCombinedAccuracy class & rated output (VA)Short-time thermal current (kA)Rated dynamic current (kA)Weight (kg)
20-800.2(5)/0.5 0.2(5)/0.5P 0.5/10P0.2(5): 10, 0.5: 15, 10P15: 20, 10P20: 2580/1In200/1In35
1000.2(5)/0.5 0.2(5)/0.5P 0.5/10P0.2(5): 10, 0.5: 15, 10P15: 20, 10P20: 2561535
1500.2(5)/0.5 0.2(5)/0.5P 0.5/10P0.2(5): 10, 0.5: 15, 10P15: 20, 10P20: 2582035
2000.2(5)/0.5 0.2(5)/0.5P 0.5/10P0.2(5): 10, 0.5: 15, 10P15: 20, 10P20: 25123035
3000.2(5)/0.5 0.2(5)/0.5P 0.5/10P0.2(5): 10, 0.5: 15, 10P15: 20, 10P20: 25164035
4000.2(5)/0.5 0.2(5)/0.5P 0.5/10P0.2(5): 10, 0.5: 15, 10P15: 20, 10P20: 25246035
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LFZZB5-10 — click image to zoom / view original.

Product Overview

About This Product

LFZZB5-10

The LFZZB5-10 is a 10 kV indoor single-phase current transformer built with a dry epoxy resin casting, a construction that removes the need for oil handling and gives the winding a solid dielectric. Its rectangular form suits panel layouts where space is tight, and the unit weighs 35 kg.

The secondary is available as 5 A or 1 A, and the accuracy combinations cover metering and protection duties: 0.2(5) at 10 VA, 0.5 at 15 VA, 10P15 at 20 VA and 10P20 at 25 VA. Short-time thermal current and rated dynamic stability scale with the primary rating, reaching 80/1In and 200/1In respectively at the lowest primary currents. Insulation is rated 12/42/75kV at 50/60 Hz. This indoor unit is not for outdoor open-air installation, and the secondary must never be open-circuited while energized. Compliance follows the GB/T 20840 series, with type-test evidence and routine documents available [On Request]. Typical deployment is in wind, photovoltaic and storage step-up collection systems, where the unit is installed indoors. Before energization, check insulation resistance, polarity and ratio. Custom ratios and accuracy classes, sample support and the document package are quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs