LFZZJ-12 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 5VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor 12kV epoxy cast current transformer for medium-voltage switchgear, suitable for metering and protection up to 800A.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LFZZJ-12 | Factory nameplate marking |
| Primary Voltage | 12kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 5VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q: Can this CT be used for both metering and protection?
A: Yes, it offers accuracy combinations 0.2S/5P or 0.5S/5P, suitable for both metering and protection.
Q: What is the rated secondary current?
A: The secondary current is 5A (or 1A optional).
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 0.2 (S) | Accuracy class & rated output (VA) COSφ=0.8 0.5 (S) | Accuracy class & rated output (VA) COSφ=0.8 5P10 | Accuracy class & rated output (VA) COSφ=0.8 5P15 | Short-time thermal current I1n (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| 5-15 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 150/1tn | 375/1tn | 21 |
| 20 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 5 | 12.5 | 21 |
| 30-40 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 8 | 20 | 21 |
| 50-60 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 10 | 25 | 21 |
| 75 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 16 | 40 | 21 |
| 100-200 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 20 | 50 | 21 |
| 300-400 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 25 | 63 | 21 |
| 500-600 | 0.2(S)/5P 0.5(S)/5P | 20 | 20 | 20 | 15 | 31.5 | 80 | 21 |
| 800 | 0.2(S)/5P 0.5(S)/5P | 20 | 20 | 25 | 15 | 31.5 | 80 | 21 |
Dimension & outline drawing of LFZZJ-12 — click image to zoom / view original.
The LFZZJ-12 is an indoor single-phase epoxy resin cast current transformer for 12 kV systems, designed to step primary current down to a 5 A secondary for metering and protection in accordance with IEC 61869, GB/T 20840 and IEEE C57.13. Its dry epoxy cast insulation and multi-grade winding design suit it to indoor switchgear, where it avoids the oil handling and spill risk of oil-immersed units and the gas management of SF6 designs. Accuracy classes 0.2S and 0.5S are available with rated outputs of 10 VA and 20 VA, and protection cores are offered as 5P10 and 5P15 at 15 VA and 10 VA respectively, with short-time thermal and dynamic ratings tabulated per primary current. Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Secondary terminals follow the nameplate marking; earth the secondary at one point and never open-circuit it while energized.
The unit is limited to indoor 12 kV service and must not be applied above that class. Custom ratios and accuracy combinations, documentation packages and export packing with after-sales support are available on request; weight is 21 kg.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.