Zero sequence current transformer for 35kV and below voltage systems. Used for cable ground protection in small grounding current systems. Rated frequency 50Hz or 60Hz. Available in Φ75, Φ110, Φ125 inner diameter sizes. Primary insulation guaranteed by cable, secondary winding insulation tested. Compliant with IEC 61869 and GB/T 20840 standards. Matching relay model DL-11/0.2, epoxy resin cast construction.
Zero-sequence current transformer for 35kV and below systems, designed for cable ground fault protection in small grounding current systems. Suitable for outdoor pole-mounted circuit breaker applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LJZ-75-110-125 | Factory nameplate marking |
| Primary Voltage | Up to 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
Connect secondary terminals 1S1 and 1S2 to the protection relay. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure the primary cable passes through the CT window (Φ75/Φ110/Φ125) and is properly insulated for the system voltage.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: Up to 35kV.
Q: What are the available inner diameters?
A: Φ75, Φ110, and Φ125.
Q: What standards does it comply with?
A: IEC 61869 and GB/T 20840.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Connecting lead resistance (Ω) | Total secondary external impedance (Ω) | Relay pickup current (A) | Sensitivity (A) | Relay scale (A) |
|---|---|---|---|---|
| 1 | ≤10 | 0.1 | ≤10 | 0.1-0.2 |
Dimension & outline drawing of LJZ-75-110-125 — click image to zoom / view original.
The LJZ-Φ75/110/125 is a 10 kV outdoor three-phase integrated current transformer with zero-sequence detection, built to the IEC 61869 and GB/T 20840 standards framework and intended for cable ground-fault protection on pole-mounted circuit breakers. Its dry epoxy resin cast body is suited to outdoor service, where the insulation system must tolerate the environmental exposure of an overhead installation; specific protection figures are [On Request].
The unit is a zero-sequence CT for systems up to 35 kV, offered in Φ75, Φ110 and Φ125 cable-passing sizes, and is positioned for cable ground protection rather than metering-class duties. For the matched sensitivity row, the secondary external total impedance is ≤10 Ω with a relay pickup current of 0.1 A and a sensitivity of ≤10 A at a relay setting of 0.1-0.2 A; accuracy class and rated output are [On Request].
Deployment is on pole-mounted breakers in cable ground-fault protection, with secondary wiring per the nameplate terminal diagram and the secondary earthed at one point. The secondary must never be open-circuited while energized. Ratios and accuracy classes can be customized, and export packing and after-sales support are available on inquiry.
Same product family, different ratings — compare before you specify.
10kV Indoor Epoxy Cast Metering Current Transformer
10kV indoor epoxy resin cast current transformer specially designed for grid energy metering. Dual windings support 0.2S high-precision metering and protection. Rated output 10-15VA, primary current range 20A to 2000A. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge design ensures metering accuracy. Vacuum epoxy casting process, moisture and salt-spray resistant. Suitable for State Grid metering applications, customizable ratio.
35kV Indoor Epoxy Cast Current Transformer for Grid Metering
35kV indoor epoxy resin cast current transformer for power grid metering. Dual windings for 0.2S high-precision metering and protection. Rated output 10-15VA, wide primary current range. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge ensures long-term metering accuracy. Vacuum epoxy casting, compact pillar design, excellent insulation performance. Suitable for 35kV grid metering applications, customizable ratio.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.