KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLJZN1-35
LJZN1-35 35kV Indoor Epoxy Cast Current Transformer for Grid Metering
35kVLJZN1-35
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A or 1A (0.2S metering class)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LJZN1-35

LJZN1-35 35kV Indoor Epoxy Cast Current Transformer for Grid Metering

35kV indoor epoxy resin cast current transformer for power grid metering. Dual windings for 0.2S high-precision metering and protection. Rated output 10-15VA, wide primary current range. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge ensures long-term metering accuracy. Vacuum epoxy casting, compact pillar design, excellent insulation performance. Suitable for 35kV grid metering applications, customizable ratio.

Key Engineering Advantages

  • 35kV metering pillar CT
  • 0.2S accuracy
  • ultra-low partial discharge
  • dual windings
  • IEC compliant
  • compact design
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LJZN1-35

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A or 1A
Metering & Protection Class:0.2S metering class
Rated Output Burden:10-15VA
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Environmental Class:Indoor pillar-type epoxy resin cast
Standards Conformance:IEC 61869, GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

35kV power grid metering
GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 35kV epoxy cast current transformer with 0.2S metering accuracy, dual windings, and IEC compliance. Suitable for grid metering applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869, GB/T 20840
Model CodeLJZN1-35Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class0.2S metering classAccuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden10-15VABurden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869, GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentIndoor pillar-type epoxy resin castPer datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 35kV indoor switchgear metering
  • Revenue metering with 0.2S accuracy
  • Protection and metering combined applications
  • Indoor installations with dry insulation requirements

Not Recommended For

  • Outdoor installations without additional enclosure
  • High-voltage systems above 35kV
  • Applications requiring class 0.1 accuracy
  • Gas-insulated switchgear (GIS) applications

Topology & Wiring

For current transformer: secondary terminals 1S1/1S2 for metering winding, 2S1/2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal conventions.

Standards & Compliance

Compliant with: IEC 61869, GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the accuracy class of this CT?

A: 0.2S metering class.

Q: What is the rated burden?

A: 10-15VA.

Q: Is it suitable for outdoor use?

A: No, it is designed for indoor use only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LJZN1-35
9 cols · 14 rows

State Grid metering Current Transformer — Technical Data

Voltage class (kV)Rated primary current (A)Accuracy classCombinedRated output (VA)Rated dynamic current (kA)Short-time thermal current (kA)Rated output (VA)Rated dynamic current (kA)Short-time thermal current (kA)
10, 20200.2S10525212.5
10, 20300.2S10525220
10, 20400.2S10525220
10, 20500.2S10525240
10, 20750.2S10525240
10, 20100-2000.2S105220265
10, 20300-5000.2S105225463
10, 20600-7500.2S105231.54100
10, 201000-20000.2S1052404100
10, 20500.2S1552404100
351000.2S1552820
351500.2S155216240
35200-3000.2S155225463
35400-6000.2S155231.5480
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LJZN1-35 — click image to zoom / view original.

Product Overview

About This Product

LJZN1-35

When metering points on a 35kV indoor network run at light load, saturation and ratio error can quietly erode billing accuracy. The LJZN1-35 is a 35kV indoor pillar-type current transformer built to address that, converting primary current to a 5A or 1A secondary for grid metering at 50/60Hz.

Its dry epoxy resin cast body carries dual windings, with the 0.2S metering class and rated burden of 10-15VA supporting accurate measurement across the load range. Compared with oil-immersed or SF6 designs, the dry cast insulation removes liquid and gas handling from the indoor installation, while the compact pillar format suits switchgear and ring-main cubicles. The unit is manufactured to IEC 61869 and GB/T 20840, and type and routine test documentation is available [On Request].

Intended for indoor 35kV metering, it should not be applied where the primary current or burden falls outside the nameplate ratings; overspecifying accuracy class only adds cost. Never open-circuit the secondary while energized. Mounting dimensions, weight and terminal arrangement are given on the outline drawing and nameplate, with customized ratios and documentation packages quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LJZN1-10 10kV Indoor Epoxy Cast Metering Current Transformer
10kV
Current Transformer50/60Hz

LJZN1-10

10kV Indoor Epoxy Cast Metering Current Transformer

10kV indoor epoxy resin cast current transformer specially designed for grid energy metering. Dual windings support 0.2S high-precision metering and protection. Rated output 10-15VA, primary current range 20A to 2000A. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge design ensures metering accuracy. Vacuum epoxy casting process, moisture and salt-spray resistant. Suitable for State Grid metering applications, customizable ratio.

Accuracy Class0.2S metering class
Insulation TypeDry Epoxy Resin
Rated Burden10-15VA
ComplianceIEC 61869
View Specs
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1765

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs