35kV indoor epoxy resin cast current transformer for power grid metering. Dual windings for 0.2S high-precision metering and protection. Rated output 10-15VA, wide primary current range. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge ensures long-term metering accuracy. Vacuum epoxy casting, compact pillar design, excellent insulation performance. Suitable for 35kV grid metering applications, customizable ratio.
Indoor 35kV epoxy cast current transformer with 0.2S metering accuracy, dual windings, and IEC compliance. Suitable for grid metering applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LJZN1-35 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | 0.2S metering class | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 10-15VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Indoor pillar-type epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
For current transformer: secondary terminals 1S1/1S2 for metering winding, 2S1/2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal conventions.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the accuracy class of this CT?
A: 0.2S metering class.
Q: What is the rated burden?
A: 10-15VA.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Voltage class (kV) | Rated primary current (A) | Accuracy classCombined | Rated output (VA) | Rated dynamic current (kA) | Short-time thermal current (kA) | Rated output (VA) | Rated dynamic current (kA) | Short-time thermal current (kA) |
|---|---|---|---|---|---|---|---|---|
| 10, 20 | 20 | 0.2S | 10 | 5 | 2 | 5 | 2 | 12.5 |
| 10, 20 | 30 | 0.2S | 10 | 5 | 2 | 5 | 2 | 20 |
| 10, 20 | 40 | 0.2S | 10 | 5 | 2 | 5 | 2 | 20 |
| 10, 20 | 50 | 0.2S | 10 | 5 | 2 | 5 | 2 | 40 |
| 10, 20 | 75 | 0.2S | 10 | 5 | 2 | 5 | 2 | 40 |
| 10, 20 | 100-200 | 0.2S | 10 | 5 | 2 | 20 | 2 | 65 |
| 10, 20 | 300-500 | 0.2S | 10 | 5 | 2 | 25 | 4 | 63 |
| 10, 20 | 600-750 | 0.2S | 10 | 5 | 2 | 31.5 | 4 | 100 |
| 10, 20 | 1000-2000 | 0.2S | 10 | 5 | 2 | 40 | 4 | 100 |
| 10, 20 | 50 | 0.2S | 15 | 5 | 2 | 40 | 4 | 100 |
| 35 | 100 | 0.2S | 15 | 5 | 2 | 8 | 2 | 0 |
| 35 | 150 | 0.2S | 15 | 5 | 2 | 16 | 2 | 40 |
| 35 | 200-300 | 0.2S | 15 | 5 | 2 | 25 | 4 | 63 |
| 35 | 400-600 | 0.2S | 15 | 5 | 2 | 31.5 | 4 | 80 |
Dimension & outline drawing of LJZN1-35 — click image to zoom / view original.
When metering points on a 35kV indoor network run at light load, saturation and ratio error can quietly erode billing accuracy. The LJZN1-35 is a 35kV indoor pillar-type current transformer built to address that, converting primary current to a 5A or 1A secondary for grid metering at 50/60Hz.
Its dry epoxy resin cast body carries dual windings, with the 0.2S metering class and rated burden of 10-15VA supporting accurate measurement across the load range. Compared with oil-immersed or SF6 designs, the dry cast insulation removes liquid and gas handling from the indoor installation, while the compact pillar format suits switchgear and ring-main cubicles. The unit is manufactured to IEC 61869 and GB/T 20840, and type and routine test documentation is available [On Request].
Intended for indoor 35kV metering, it should not be applied where the primary current or burden falls outside the nameplate ratings; overspecifying accuracy class only adds cost. Never open-circuit the secondary while energized. Mounting dimensions, weight and terminal arrangement are given on the outline drawing and nameplate, with customized ratios and documentation packages quoted on request.
Same product family, different ratings — compare before you specify.
10kV Indoor Epoxy Cast Metering Current Transformer
10kV indoor epoxy resin cast current transformer specially designed for grid energy metering. Dual windings support 0.2S high-precision metering and protection. Rated output 10-15VA, primary current range 20A to 2000A. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge design ensures metering accuracy. Vacuum epoxy casting process, moisture and salt-spray resistant. Suitable for State Grid metering applications, customizable ratio.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.