LMK-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
LMK-0.66 is a low-voltage current transformer for indoor use, suitable for current measurement and protection in LV distribution systems up to 0.66kV.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LMK-0.66 | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / GB/T 20840 for terminal markings and safety.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the rated primary voltage of the LMK-0.66?
A: The rated primary voltage is 0.66kV.
Q: What accuracy classes are available?
A: Accuracy classes 0.2, 0.5, and 1.0 are available.
Q: Can the current ratio be customized?
A: Yes, the current ratio can be customized as per requirements.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated current ratio (A) | Rated output (VA) | Accuracy class | Primary current / turns | Turns through core | Overall dimensions | Aperture dimensions (W×H) | Mounting dimensions (W×H) | ||
|---|---|---|---|---|---|---|---|---|---|---|
| W | D | H | ||||||||
| LMK1-0.66/30 (BH-0.66/30) | 30/5 | 1 | 0.5 | 1 | 1 | 78 | 32 | 78 | 30×30 | 82×31 |
| 40/5 | 1 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 50/5 | 1 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 60/5 | 2 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 75/5 | 2 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 100/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 150/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/40 (BH-0.66/40) | 100/5 | 2.5 | 0.5 | 1 | 1 | 85 | 42 | 78 | 30×30 | 82×31 |
| 150/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/60 (BH-0.66/60) | 300/5 | 5 | 0.5 | 1 | 1 | 90 | 52 | 80 | 30×30 | 82×31 |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/80 (BH-0.66/80) | 400/5 | 5 | 0.5 | 1 | 1 | 105 | 70 | 100 | 40×40 | 82×31 |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/100 (BH-0.66/100) | 600/5 | 5 | 0.5 | 1 | 1 | 120 | 80 | 110 | 50×50 | 82×31 |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/30 (SDH-0.66/30) | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 40 | 100 | 30×30 | 82×30 |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/40 (SDH-0.66/40) | 200/5 | 2.5 | 0.5 | 1 | 1 | 90 | 45 | 110 | 30×30 | 82×30 |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/60 (SDH-0.66/60) | 400/5 | 5 | 0.5 | 1 | 1 | 102 | 60 | 140 | 40×40 | 82×30 |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/80 (SDH-0.66/80) | 600/5 | 5 | 0.5 | 1 | 1 | 108 | 80 | 150 | 50×50 | 82×30 |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/30 (LN-0.66/30) | 150/5 | 2.5 | 0.5 | 1 | 1 | 118 | 40 | 120 | 30×30 | 82×30 |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/40 (LN-0.66/40) | 200/5 | 2.5 | 0.5 | 1 | 1 | 140 | 60 | 120 | 40×40 | 82×30 |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/60 (LN-0.66/60) | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 60 | 120 | 40×40 | 82×30 |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/80 (LN-0.66/80) | 600/5 | 5 | 0.5 | 1 | 1 | 187 | 80 | 120 | 50×50 | 82×30 |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/100 (LN-0.66/100) | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 80 | 120 | 50×50 | 82×30 |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMZ1-0.66/30 (BH-0.66/30) | 100/5 | 2.5 | 0.5 | 1 | 1 | 248 | 88 | 110 | 30×30 | 228×80 |
| 150/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMZ1-0.66/40 (BH-0.66/40) | 200/5 | 2.5 | 0.5 | 1 | 1 | 270 | 90 | 110 | 30×30 | 228×80 |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMZ1-0.66/60 (BH-0.66/60) | 300/5 | 5 | 0.5 | 1 | 1 | 300 | 100 | 110 | 30×30 | 228×80 |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
Dimension & outline drawing of LMK-0.66 — click image to zoom / view original.
The LMK-0.66 is an indoor low-voltage current transformer rated 0.66 kV, used to step primary current down to a 5 A or 1 A secondary for metering and protection in AC systems at 50/60 Hz. Its accuracy classes of 0.2, 0.5 and 1.0 make it relevant where billing and energy settlement depend on repeatable measurement.
Dry epoxy resin insulation encapsulates the windings, and each unit is checked at manufacture for ratio and polarity; the routine test and calibration documentation accompanying a delivery is confirmed at order. Secondary ratings cover 1 A and 5 A, with rated burdens of 1.5 VA, 2.5 VA, 5 VA, 10 VA, 15 VA and 20 VA, so the burden can be matched to the connected meter or relay. Compared with oil-immersed or SF6 designs, the dry resin construction suits indoor panels where liquid and gas handling are unwanted.
Deployment is indoor: switchgear compartments, busbar current measurement and protection circuits. Earth the secondary at one point and never open-circuit it while energized. The unit is not for outdoor exposure. Ratio and accuracy customization, sample and type-test support, and the document package are quoted on request.
Same product family, different ratings — compare before you specify.
Indoor Low Voltage Protection Current Transformer 0.66kV
Indoor low voltage protection current transformer, 0.66kV rated, epoxy resin casting type, for protection applications in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple protection accuracy classes 5P, 10P. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
Indoor Low Voltage Bury-plug Current Transformer 0.66kV
Indoor low voltage bury-plug type current transformer, 0.66kV rated, epoxy resin casting type, for current measurement, control and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Bury-plug terminal design with connection pipes, easy and safe wiring. Compact size, transparent dust cover, clean and safe. Wide range of current ratios available. Customizable ratios and specifications.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.