KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMK-0.66
LMK-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kVLMK-0.66
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A/1A (0.2/0.5/1.0)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMK-0.66

LMK-0.66 Indoor Low Voltage Current Transformer 0.66kV

LMK-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Key Engineering Advantages

  • LV current transformer
  • 0.66kV
  • epoxy resin
  • multiple ratios
  • compact size
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMK-0.66

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A/1A
Metering & Protection Class:0.2/0.5/1.0
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LMK-0.66 is a low-voltage current transformer for indoor use, suitable for current measurement and protection in LV distribution systems up to 0.66kV.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeLMK-0.66Factory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class0.2/0.5/1.0Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low-voltage switchgear and panel mounting
  • Current measurement and protection in LV distribution systems
  • Applications requiring accuracy classes 0.2, 0.5, or 1.0
  • Customizable current ratios and specifications
  • Dry epoxy resin insulation for indoor environments

Not Recommended For

  • Outdoor installation without additional protection
  • High-voltage systems above 0.66kV
  • Applications requiring high-accuracy metering beyond class 0.2
  • Environments with extreme temperatures or humidity without derating

Topology & Wiring

Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / GB/T 20840 for terminal markings and safety.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the rated primary voltage of the LMK-0.66?

A: The rated primary voltage is 0.66kV.

Q: What accuracy classes are available?

A: Accuracy classes 0.2, 0.5, and 1.0 are available.

Q: Can the current ratio be customized?

A: Yes, the current ratio can be customized as per requirements.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMK-0.66
11 cols · 164 rows

LMK (1,2,3)-0.66, BH, SDH, LN Series Current Transformer

ModelRated current ratio (A)Rated output (VA)Accuracy classPrimary current / turnsTurns through coreOverall dimensionsAperture dimensions (W×H)Mounting dimensions (W×H)
WDH
LMK1-0.66/30 (BH-0.66/30)30/510.51178327830×3082×31
40/510.511—————
50/510.511—————
60/520.511—————
75/520.511—————
100/52.50.511—————
150/52.50.511—————
200/52.50.511—————
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
LMK1-0.66/40 (BH-0.66/40)100/52.50.51185427830×3082×31
150/52.50.511—————
200/52.50.511—————
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
LMK1-0.66/60 (BH-0.66/60)300/550.51190528030×3082×31
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
LMK1-0.66/80 (BH-0.66/80)400/550.5111057010040×4082×31
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
LMK1-0.66/100 (BH-0.66/100)600/550.5111208011050×5082×31
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
2500/550.511—————
3000/550.511—————
LMK2-0.66/30 (SDH-0.66/30)150/52.50.511874010030×3082×30
200/52.50.511—————
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
LMK2-0.66/40 (SDH-0.66/40)200/52.50.511904511030×3082×30
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
LMK2-0.66/60 (SDH-0.66/60)400/550.5111026014040×4082×30
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
2500/550.511—————
LMK2-0.66/80 (SDH-0.66/80)600/550.5111088015050×5082×30
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
2500/550.511—————
3000/550.511—————
LMK3-0.66/30 (LN-0.66/30)150/52.50.5111184012030×3082×30
200/52.50.511—————
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
LMK3-0.66/40 (LN-0.66/40)200/52.50.5111406012040×4082×30
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
LMK3-0.66/60 (LN-0.66/60)400/550.5111406012040×4082×30
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
2500/550.511—————
LMK3-0.66/80 (LN-0.66/80)600/550.5111878012050×5082×30
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
2500/550.511—————
3000/550.511—————
LMK3-0.66/100 (LN-0.66/100)1000/550.5112278012050×5082×30
1200/550.511—————
1500/550.511—————
2000/550.511—————
2500/550.511—————
3000/550.511—————
LMZ1-0.66/30 (BH-0.66/30)100/52.50.5112488811030×30228×80
150/52.50.511—————
200/52.50.511—————
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
LMZ1-0.66/40 (BH-0.66/40)200/52.50.5112709011030×30228×80
250/52.50.511—————
300/550.511—————
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
LMZ1-0.66/60 (BH-0.66/60)300/550.51130010011030×30228×80
400/550.511—————
500/550.511—————
600/550.511—————
750/550.511—————
800/550.511—————
1000/550.511—————
1200/550.511—————
1500/550.511—————
2000/550.511—————
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMK-0.66 — click image to zoom / view original.

Product Overview

About This Product

LMK-0.66

The LMK-0.66 is an indoor low-voltage current transformer rated 0.66 kV, used to step primary current down to a 5 A or 1 A secondary for metering and protection in AC systems at 50/60 Hz. Its accuracy classes of 0.2, 0.5 and 1.0 make it relevant where billing and energy settlement depend on repeatable measurement.

Dry epoxy resin insulation encapsulates the windings, and each unit is checked at manufacture for ratio and polarity; the routine test and calibration documentation accompanying a delivery is confirmed at order. Secondary ratings cover 1 A and 5 A, with rated burdens of 1.5 VA, 2.5 VA, 5 VA, 10 VA, 15 VA and 20 VA, so the burden can be matched to the connected meter or relay. Compared with oil-immersed or SF6 designs, the dry resin construction suits indoor panels where liquid and gas handling are unwanted.

Deployment is indoor: switchgear compartments, busbar current measurement and protection circuits. Earth the secondary at one point and never open-circuit it while energized. The unit is not for outdoor exposure. Ratio and accuracy customization, sample and type-test support, and the document package are quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMK-0.66P Indoor Low Voltage Protection Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

LMK-0.66P

Indoor Low Voltage Protection Current Transformer 0.66kV

Indoor low voltage protection current transformer, 0.66kV rated, epoxy resin casting type, for protection applications in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple protection accuracy classes 5P, 10P. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.

Accuracy Class5P/10P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LMK8-0.66 Indoor Low Voltage Bury-plug Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

LMK8-0.66

Indoor Low Voltage Bury-plug Current Transformer 0.66kV

Indoor low voltage bury-plug type current transformer, 0.66kV rated, epoxy resin casting type, for current measurement, control and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Bury-plug terminal design with connection pipes, easy and safe wiring. Compact size, transparent dust cover, clean and safe. Wide range of current ratios available. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs