Indoor low voltage protection current transformer, 0.66kV rated, epoxy resin casting type, for protection applications in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple protection accuracy classes 5P, 10P. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
LMK-0.66P is a low-voltage protection current transformer for indoor use, suitable for protection applications in LV distribution systems.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LMK-0.66P | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 5P/10P | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main protection winding. If a second winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869 / GB/T 20840 for installation.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation type?
A: Dry epoxy resin.
Q: What accuracy classes are available?
A: 5P and 10P.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Overall dimensions | Window dimensions (mm) a×e | ||
|---|---|---|---|---|
| W | D | H | ||
| LMK(1,2,3)-0.66/60P | 129 | 75 | 200 | 63×54 |
| LMK(1,2,3)-0.66/80P | 164 | 75 | 185 | 83×55 |
| LMK(1,2,3)-0.66/100P | 190 | 75 | 185 | 104×57 |
| LMK(1,2,3)-0.66/120P | 220 | 91 | 217 | 129×81 |
| LMK(1,2,3)-0.66/170P | 255 | 60 | 215 | 167×106 |
| LMK(1,2,3)-0.66/220P | 279 | 60 | 184 | 225×57 |
Dimension & outline drawing of LMK-0.66P — click image to zoom / view original.
The LMK-0.66P is an indoor low-voltage protection current transformer with a 0.66kV primary voltage rating, built around a dry epoxy resin insulation system. The casting process encapsulates the core and windings to form a solid, void-free body that supports the 5P/10P protection classes and the 50/60Hz operating frequency.
Secondary output is 5A/1A, and the accuracy class is 5P/10P; rated burden in VA and short-time thermal ratings are stated on the nameplate and the official datasheet. This unit sits in the indoor protection segment of the low-voltage CT range, where the epoxy body suits switchgear and ring-main enclosures rather than outdoor exposure. It is manufactured to IEC 61869 and GB/T 20840, and test certificates and routine reports are available [On Request].
Typical deployment is inside low-voltage switchgear and distribution panels for protection relaying. Mount it on the primary conductor, earth the secondary at one point, and never open-circuit the secondary while the primary is energized. The indoor rating excludes outdoor open-air installation. Ratio and accuracy-class combinations can be customized, and the document package and delivery terms are confirmed at inquiry.
Same product family, different ratings — compare before you specify.
Indoor Low Voltage Bury-plug Current Transformer 0.66kV
Indoor low voltage bury-plug type current transformer, 0.66kV rated, epoxy resin casting type, for current measurement, control and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Bury-plug terminal design with connection pipes, easy and safe wiring. Compact size, transparent dust cover, clean and safe. Wide range of current ratios available. Customizable ratios and specifications.
Indoor Low Voltage Current Transformer 0.66kV
LMK-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.