KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZ1-2-3-0.66
LMZ1,2,3-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kVLMZ1-2-3-0.66
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A/1A (0.2/0.5/1.0)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZ1-2-3-0.66

LMZ1,2,3-0.66 Indoor Low Voltage Current Transformer 0.66kV

Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.

Key Engineering Advantages

  • LV current transformer
  • 0.66kV
  • epoxy resin
  • multiple ratios
  • compact size
  • IEC 61869 standard
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZ1-2-3-0.66

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A/1A
Metering & Protection Class:0.2/0.5/1.0
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor LV CT for 0.66kV systems, suitable for metering and protection in switchgear and panels. Confirm ratio and accuracy class per application.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeLMZ1-2-3-0.66Factory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class0.2/0.5/1.0Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low voltage switchgear and panels
  • Current measurement and protection in LV distribution
  • Metering applications with accuracy class 0.2 or 0.5
  • 50/60Hz systems up to 0.66kV

Not Recommended For

  • Outdoor installations without additional protection
  • High voltage systems above 1kV
  • DC current measurement
  • High accuracy revenue metering requiring class 0.1 or better

Topology & Wiring

connect primary in series with the line. Secondary terminals are 1S1 and 1S2 (protection winding if present: 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / IEEE C57.13 terminal conventions.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the maximum system voltage for this CT?

A: Rated for 0.66kV systems.

Q: What accuracy classes are available?

A: 0.2, 0.5, and 1.0.

Q: Can it be used outdoors?

A: No, it is designed for indoor use only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZ1-2-3-0.66
6 cols · 5 rows

LMZ (1,2,3)-0.66 Series Current Transformer

ModelRated primary current (A)0.2 class0.5 class1 classPrimary Turns through core
LMZ(1,2,3)-0.66100--51
LMZ(1,2,3)-0.66200-400557.51
LMZ(1,2,3)-0.66500-8001010151
LMZ(1,2,3)-0.661000-15001515201
LMZ(1,2,3)-0.662000-30002020251
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZ1-2-3-0.66 — click image to zoom / view original.

Product Overview

About This Product

LMZ1-2-3-0.66

This is an indoor low-voltage current transformer for 0.66kV switchgear and distribution compartments, stepping primary current down to a 5A or 1A secondary for metering and protection. Its dry epoxy resin insulation and compact moulded body suit panel mounting where space is tight.

Accuracy classes 0.2, 0.5 and 1.0 are available, with rated outputs of 5VA to 25VA depending on the primary current range; for example the 2000–3000A range carries 20VA at class 0.2 and 25VA at class 1.0, with a single primary through-turn. Each unit is routine-tested for ratio and polarity before dispatch, and type and routine test reports to IEC 61869 and GB/T 20840 are available [On Request].

Typical deployment is in heavy-industry distribution — metallurgy, mining, cement and chemical plants — indoors only. Observe P1/P2 orientation, earth the secondary at one point, and never open-circuit the secondary while energized. For OEM branding, custom ratios and document packages, contact the factory.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMZ1D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ1D-SKX1

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 75A, accuracy 0.2S/0.5S, for metering in low-voltage distribution systems.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden5VA
View Specs
LMZ1D-SKX2 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ1D-SKX2

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast low-voltage current transformer of State Grid standard, primary rated current 100-150A, accuracy class 0.2S/0.5S, applied for metering in low-voltage power distribution systems.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden5VA
View Specs
CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs