Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 75A, accuracy 0.2S/0.5S, for metering in low-voltage distribution systems.
LMZ1D-SKX1 is a 0.66kV indoor current transformer with 75A primary and 0.2S/0.5S accuracy, ideal for revenue metering in low-voltage distribution panels. It is not suitable for outdoor or high-voltage applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LMZ1D-SKX1 | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 5VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window; secondary terminals are 1S1 and 1S2 (if dual secondary, 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point per IEC 61869-2.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary current rating?
A: The primary rated current is 75A.
Q: What accuracy classes are available?
A: Accuracy classes are 0.2S and 0.5S.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current (A) | Rated output (VA) 0.2 class | Rated output (VA) 0.5 class | Primary turns |
|---|---|---|---|---|
| LMZ1D-SKX1 | 75 | 5 | 5 | 1 |
| LMZ2D-SKX2 | 100-150 | 5 | 5 | 1 |
| LMZ3D-SKX1 | 200-600 | 5 | 5 | 1 |
| LMZ4D-SKX1 | 600-800 | 10 | 10 | 1 |
| LMZ4D-SKX1 | 800-1500 | 10 | 10 | 1 |
Dimension & outline drawing of LMZ1D-SKX1 — click image to zoom / view original.
The LMZ1D-SKX1 is a 0.66kV indoor current transformer that addresses light-load metering error and saturation in compact switchgear, where space is limited and accurate low-current measurement is required.
Its dry epoxy resin insulation and single-turn primary winding suit the 75A primary current, with a 5A secondary output at 50/60Hz. Accuracy classes 0.2S/0.5S and a 5VA rated burden provide precise measurement across the load range. This unit is positioned for indoor applications; outdoor environmental protection is [On Request].
Compliance follows the State Grid standard, with test certificates and documentation available. Typical deployment is in medium-voltage switchgear, ring main units, and central cabinets. Before energizing, verify the secondary burden does not exceed 5VA and confirm wiring and earthing. The secondary must never be open-circuited while energized, as this can cause dangerous voltages. For customization of ratio, accuracy class, or documentation packages, consult the factory.
Same product family, different ratings — compare before you specify.
State Grid Standard 0.66kV Current Transformer
Indoor epoxy cast low-voltage current transformer of State Grid standard, primary rated current 100-150A, accuracy class 0.2S/0.5S, applied for metering in low-voltage power distribution systems.
Indoor Low Voltage Current Transformer 0.66kV
Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.