KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZ1D-SKX1
LMZ1D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kVLMZ1D-SKX1
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A (0.2S/0.5S)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZ1D-SKX1

LMZ1D-SKX1 State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 75A, accuracy 0.2S/0.5S, for metering in low-voltage distribution systems.

Key Engineering Advantages

  • 75A primary current
  • 0.2S/0.5S precision
  • State Grid standard
  • 0.66kV
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZ1D-SKX1

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A
Metering & Protection Class:0.2S/0.5S
Rated Output Burden:5VA
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LMZ1D-SKX1 is a 0.66kV indoor current transformer with 75A primary and 0.2S/0.5S accuracy, ideal for revenue metering in low-voltage distribution panels. It is not suitable for outdoor or high-voltage applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLMZ1D-SKX1Factory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5ARatio check at rated frequency
Accuracy Class0.2S/0.5SAccuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden5VABurden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Low-voltage metering (0.66kV class)
  • Indoor switchgear and distribution boards
  • Revenue billing with 0.2S/0.5S accuracy
  • 50/60Hz systems

Not Recommended For

  • Outdoor installations
  • High-voltage systems above 1kV
  • Protection applications requiring high overcurrent capability
  • DC systems

Topology & Wiring

Connect primary through the window; secondary terminals are 1S1 and 1S2 (if dual secondary, 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point per IEC 61869-2.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary current rating?

A: The primary rated current is 75A.

Q: What accuracy classes are available?

A: Accuracy classes are 0.2S and 0.5S.

Q: Is it suitable for outdoor use?

A: No, it is designed for indoor use only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZ1D-SKX1
5 cols · 5 rows

LMZ1 (2,3,4)D Series Current Transformer

ModelRated primary current (A)Rated output (VA) 0.2 classRated output (VA) 0.5 classPrimary turns
LMZ1D-SKX175551
LMZ2D-SKX2100-150551
LMZ3D-SKX1200-600551
LMZ4D-SKX1600-80010101
LMZ4D-SKX1800-150010101
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZ1D-SKX1 — click image to zoom / view original.

Product Overview

About This Product

LMZ1D-SKX1

The LMZ1D-SKX1 is a 0.66kV indoor current transformer that addresses light-load metering error and saturation in compact switchgear, where space is limited and accurate low-current measurement is required.

Its dry epoxy resin insulation and single-turn primary winding suit the 75A primary current, with a 5A secondary output at 50/60Hz. Accuracy classes 0.2S/0.5S and a 5VA rated burden provide precise measurement across the load range. This unit is positioned for indoor applications; outdoor environmental protection is [On Request].

Compliance follows the State Grid standard, with test certificates and documentation available. Typical deployment is in medium-voltage switchgear, ring main units, and central cabinets. Before energizing, verify the secondary burden does not exceed 5VA and confirm wiring and earthing. The secondary must never be open-circuited while energized, as this can cause dangerous voltages. For customization of ratio, accuracy class, or documentation packages, consult the factory.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMZ1D-SKX2 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ1D-SKX2

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast low-voltage current transformer of State Grid standard, primary rated current 100-150A, accuracy class 0.2S/0.5S, applied for metering in low-voltage power distribution systems.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden5VA
View Specs
LMZ1,2,3-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

LMZ1-2-3-0.66

Indoor Low Voltage Current Transformer 0.66kV

Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs