中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZ3-10
LMZ3-10 Indoor Single-phase Epoxy Resin Casting Current Transformer
10kVLMZ3-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZ3-10

LMZ3-10 Indoor Single-phase Epoxy Resin Casting Current Transformer

LMZ3-10 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • Epoxy resin casting structure
  • indoor single-phase application
  • complete accuracy grades and rated output options
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZ3-10

Electrical Parameters

Primary Rated Voltage (Un):10kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy resin CT for 35kV systems, suitable for metering and protection in RMU applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLMZ3-10Factory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor switchgear and RMU installations
  • Revenue metering with accuracy class [On Request]
  • Protection relaying with rated burden [On Request]
  • 50/60Hz power systems

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) without adapter
  • DC systems
  • High-altitude applications above [On Request] meters

Topology & Wiring

Connect primary through the window. Secondary terminals: 1S1 and 1S2 for metering (if provided), 2S1 and 2S2 for protection (if provided). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only, preferably at the switchgear earth bar. Ensure shorting links are closed before removing the CT from service.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The primary voltage is 35kV; insulation level details are [On Request].

Q: Can this CT be used outdoors?

A: No, it is designed for indoor use only.

Q: What standards does it comply with?

A: It complies with GB/T20840.1, GB/T20840.2, IEC61869-1, and IEC61869-2.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZ3-10
6 cols · 8 rows

LMZ3-10 Series Current Transformer — Technical Data

Rated primary current I1n (A)Accuracy classCombined0.20.55P10Weight (kg)
3000.2, 0.51015-8
3000.2/5P10, 0.5/5P107.57.57.58
4000.2S, 0.5S1010-8
5000.2S, 0.5S1515-8
5000.2/5P10, 0.5/5P1010103.758
6000.2S, 0.5S1515-8
6000.2/5P10, 0.5/5P10101058
8000.2S, 0.5S55-8
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZ3-10 — click image to zoom / view original.

Product Overview

About This Product

LMZ3-10

The LMZ3-10 is an indoor single-phase epoxy resin cast current transformer for 10 kV systems, used to step primary current down to a metered or protective secondary level in accordance with IEC 61869, GB/T 20840 and IEEE C57.13. Its dry epoxy resin casting insulates the primary and core assembly, and the single-phase format suits panel and switchgear mounting.

Accuracy classes 0.2, 0.5, 5P10, 0.2S and 0.5S are available with rated outputs of 5VA, 7.5VA, 10VA and 15VA at 50/60Hz; the 5P10 protective core is intended to hold its accuracy through fault-level primary currents. Compared with oil-immersed or SF6 designs, the dry cast body avoids liquid and gas handling, which suits indoor installation where that maintenance is unwanted. Type-test and routine-test documentation, including the applicable IEEE C57.13 evidence, is available [On Request].

Typical deployment includes renewable-energy collector and booster stations, where the unit is installed indoors only. Earth the secondary at one point and never open-circuit it while the primary is energized. The LMZ3-10 is not for outdoor exposure; ratios and accuracy classes can be customized, and sample and type-test support is offered on inquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMZ3D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ3D-SKX1

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 600-800A, accuracy 0.2S/0.5S.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden10VA
View Specs
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1765

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs