LMZ3-10 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for 35kV systems, suitable for metering and protection in RMU applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LMZ3-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window. Secondary terminals: 1S1 and 1S2 for metering (if provided), 2S1 and 2S2 for protection (if provided). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only, preferably at the switchgear earth bar. Ensure shorting links are closed before removing the CT from service.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The primary voltage is 35kV; insulation level details are [On Request].
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only.
Q: What standards does it comply with?
A: It complies with GB/T20840.1, GB/T20840.2, IEC61869-1, and IEC61869-2.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | 0.2 | 0.5 | 5P10 | Weight (kg) |
|---|---|---|---|---|---|
| 300 | 0.2, 0.5 | 10 | 15 | - | 8 |
| 300 | 0.2/5P10, 0.5/5P10 | 7.5 | 7.5 | 7.5 | 8 |
| 400 | 0.2S, 0.5S | 10 | 10 | - | 8 |
| 500 | 0.2S, 0.5S | 15 | 15 | - | 8 |
| 500 | 0.2/5P10, 0.5/5P10 | 10 | 10 | 3.75 | 8 |
| 600 | 0.2S, 0.5S | 15 | 15 | - | 8 |
| 600 | 0.2/5P10, 0.5/5P10 | 10 | 10 | 5 | 8 |
| 800 | 0.2S, 0.5S | 5 | 5 | - | 8 |
Dimension & outline drawing of LMZ3-10 — click image to zoom / view original.
The LMZ3-10 is an indoor single-phase epoxy resin cast current transformer for 10 kV systems, used to step primary current down to a metered or protective secondary level in accordance with IEC 61869, GB/T 20840 and IEEE C57.13. Its dry epoxy resin casting insulates the primary and core assembly, and the single-phase format suits panel and switchgear mounting.
Accuracy classes 0.2, 0.5, 5P10, 0.2S and 0.5S are available with rated outputs of 5VA, 7.5VA, 10VA and 15VA at 50/60Hz; the 5P10 protective core is intended to hold its accuracy through fault-level primary currents. Compared with oil-immersed or SF6 designs, the dry cast body avoids liquid and gas handling, which suits indoor installation where that maintenance is unwanted. Type-test and routine-test documentation, including the applicable IEEE C57.13 evidence, is available [On Request].
Typical deployment includes renewable-energy collector and booster stations, where the unit is installed indoors only. Earth the secondary at one point and never open-circuit it while the primary is energized. The LMZ3-10 is not for outdoor exposure; ratios and accuracy classes can be customized, and sample and type-test support is offered on inquiry.
Same product family, different ratings — compare before you specify.
State Grid Standard 0.66kV Current Transformer
Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 600-800A, accuracy 0.2S/0.5S.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.