10kV indoor busbar-type epoxy resin cast current transformer. Through-core design for easy installation on busbars. Rated insulation level 12/42/75kV, 50/60Hz, secondary current 5A or 1A. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting process, low partial discharge, reliable performance. Suitable for medium voltage switchgear, customizable ratio and accuracy.
LMZ9-10 is a 10kV indoor busbar-type current transformer with epoxy cast insulation, suitable for medium voltage switchgear applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LMZ9-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Indoor busbar-type epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
For current transformer (CT) wiring: Connect primary busbar through the window. Secondary terminals are 1S1 and 1S2 for the main winding; if dual ratio, additional taps may be present. Ensure secondary is never open-circuited while energized - hazardous voltage can occur. Ground the secondary circuit at one point only, preferably at the CT terminal box, to ensure safety and proper operation. Follow IEC 61869-2 and IEEE C57.13 for terminal markings and connections.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of LMZ9-10?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: Can LMZ9-10 be used outdoors?
A: No, it is designed for indoor use only. Outdoor installation would require additional weatherproofing.
Q: What are the secondary current options?
A: The secondary current can be 5A or 1A, as specified.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 (0.2 (S)) | Accuracy class & rated output (VA) COSφ=0.8 (0.5 (S)) | Accuracy class & rated output (VA) COSφ=0.8 (5 (10)P10) | Weight (kg) |
|---|---|---|---|---|---|
| 400~800 | 0.2(S) 0.5(S) 5(10)P10 | 3VA | 3VA | 2VA | 5 |
Dimension & outline drawing of LMZ9-10 — click image to zoom / view original.
The LMZ9-10 is a 10 kV indoor busbar-type single-phase current transformer intended for metering and protection duties in medium voltage switchgear, where its accuracy class directly supports fair energy settlement. The through-core, epoxy resin cast construction provides dry insulation, and each unit is routine-tested at the factory for ratio and polarity before dispatch.
With a 5 A or 1 A secondary, the LMZ9-10 offers accuracy classes 0.2(S) and 0.5(S) at 3 VA, plus 5(10)P10 at 2 VA, maintaining defined error limits from light load to full load. It complies with IEC 61869 and GB/T 20840, and a datasheet, outline drawing and test report are available [On Request]. Typical deployment covers heavy-industry distribution in metallurgy, mining, cement and chemical plants, always indoors.
Secondary terminals are marked per the nameplate; earth the secondary at one point and never open-circuit it while energized. The unit is not suitable for DC or non-standard frequencies. OEM branding and customized ratios or classes can be quoted, with a document package supplied with each delivery.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.