KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZB-20
LMZB-20 Indoor Single-phase Epoxy Resin Casting Current Transformer
20kVLMZB-20
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 20kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZB-20

LMZB-20 Indoor Single-phase Epoxy Resin Casting Current Transformer

LMZB-20 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 5A/1A. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 20kV indoor bushing-type current transformer
  • wide primary current range
  • multi accuracy classes for selection
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZB-20

Electrical Parameters

Primary Rated Voltage (Un):20kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):24/65/125kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 20kV bushing-type CT for medium-voltage switchgear, suitable for metering and protection up to 6000A.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLMZB-20Factory nameplate marking
Primary Voltage20kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)24/65/125kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium-voltage switchgear panels
  • Metering and protection applications up to 20kV
  • Primary currents from 1500A to 6000A
  • Systems with accuracy classes 0.2(S), 0.5(S), 5P10/15/20

Not Recommended For

  • Outdoor installations
  • Gas-insulated switchgear (GIS) without adapter
  • High-voltage transmission systems above 20kV
  • DC systems

Topology & Wiring

Connect primary busbar through the window. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse withstand.

Q: Can this CT be used outdoors?

A: No, it is designed for indoor use only.

Q: What secondary currents are available?

A: Secondary current is 5A or 1A.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZB-20
8 cols · 4 rows

LMZB-20 Current Transformer

Rated primary current I1n (A)Accuracy classCombined0.2(S)0.5(S)5P105P155P20Weight (kg)
15000.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P/5P 0.5(S)/5P/5P2030805030102
20000.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P/5P 0.5(S)/5P/5P20301006040102
25000.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P/5P 0.5(S)/5P/5P30501006040102
3000-60000.2(S)/0.2(S)/5P 0.2(S)/0.5(S)/5P 0.2(S)/5P/5P 0.5(S)/5P/5P30501008050102
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZB-20 — click image to zoom / view original.

Product Overview

About This Product

LMZB-20

The LMZB-20 is an indoor single-phase epoxy resin cast current transformer rated 20 kV, designed to step primary current down to 5 A or 1 A for metering and protection in 50/60 Hz systems. Its dry epoxy resin body provides the insulation, with a dielectric rating of 24/65/125 kV; details of creepage distance and winding architecture are available on the nameplate and official datasheet.

Accuracy classes include 0.2(S), 0.5(S), 5P10, 5P15 and 5P20, with rated outputs from 20 VA to 100 VA depending on the class and primary current. For example, at 1500 A the 5P10 output is 80 VA and the unit weighs 102 kg; at 2500 A the 0.2(S) output is 30 VA. The 5P cores are intended to resist saturation under fault currents, supporting reliable protection operation.

This indoor unit suits switchgear in rail, data centre, hospital and water infrastructure. Earth the secondary at one point and never open-circuit it while energized. Standard ratios are stocked; custom ratios and classes are available [On Request]. Over-specifying accuracy wastes budget. Request the datasheet, outline drawing and test reports with your inquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMZB3-10G Indoor Single-phase Epoxy Resin Casting Current Transformer
10kV
Current Transformer50/60Hz

LMZB3-10G

Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000-3000A、4000-6000A; accuracy combinations including 0.2S/0.2S、0.2S/0.5S、0.2S/10P15/10P15、0.5S/10P15/10P15, rated output values 15VA/20VA/30VA corresponding to different accuracy grades, net weight 45kg, ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LMZB3-10GWD,E 10kV Indoor Through-Core Epoxy Cast Current Transformer
10kV
Current Transformer50/60Hz

LMZB3-10GWD-E

10kV Indoor Through-Core Epoxy Cast Current Transformer

LMZB3-10GWD,E 10kV Indoor Through-Core Epoxy Cast Current Transformer (LMZB3-10GWD-E) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.

Accuracy Class0.2S, 0.5, 5P20, 5P30
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
LMZB3-10Q Indoor Single-phase Epoxy Resin Casting Current Transformer
10kV
Current Transformer50/60Hz

LMZB3-10Q

Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1200A、1500A、2000-6000A; multiple accuracy combinations like 0.2S/0.5S、0.2S/10P15、10P15/10P15、0.5S/10P15, rated output values 15VA/20VA/30VA for different grades, net weight 30kg, ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs