LMZB3-10GWD,E 10kV Indoor Through-Core Epoxy Cast Current Transformer (LMZB3-10GWD-E) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.
12kV indoor busbar-type CT with dual windings for metering and protection, suitable for MV switchgear busbar applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LMZB3-10GWD-E | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | 0.2S, 0.5, 5P20, 5P30 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Indoor busbar-type through-core epoxy cast | Per datasheet limits |
Ideal For
Not Recommended For
Connect secondary terminals 1S1/1S2 for metering winding and 2S1/2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure polarity markings are observed for proper relay operation.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: Can this CT be used for both metering and protection?
A: Yes, it has dual windings with accuracy classes 0.2S/0.5 for metering and 5P20/5P30 for protection.
Q: Is this CT suitable for outdoor use?
A: No, it is designed for indoor use only, as indicated by 'Indoor' in the product name.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Rated output (VA) 0.2 class | Rated output (VA) 0.5 class | Rated output (VA) 5P20 class | Rated output (VA) 0.2S class | Rated output (VA) 5P30 class | Rated output (VA) 0.5S class | Model |
|---|---|---|---|---|---|---|---|---|
| 50E | 0.2/0.5/5P20 | / | / | 10 | / | 10 | / | LZZBJ9-10GWA |
| 100E | 0.2/0.5/5P20 | 10 | 10 | 10 | / | 10 | / | LZZBJ9-10GWA |
| 0.2/0.5/5P20 | 10 | 10 | 10 | / | 10 | / | LZZBJ9-10GWB | |
| 200E | 0.2/0.5/5P20 | 10 | 10 | 20 | / | 20 | / | LZZBJ9-10GWB |
| 0.2/0.5/5P20 | 10 | 10 | 20 | / | 20 | / | LZZBJ9-10GWC | |
| 300E | 0.2/0.5/5P20 | 10 | 10 | 20 | / | 20 | / | LZZBJ9-10GWC |
| 400E | 0.2/0.5/5P20 | 15 | 15 | 20 | / | 20 | / | LZZBJ9-10GWC |
| 600E | 0.2/0.5/5P20 | 15 | 15 | 20 | / | 20 | / | LZZBJ9-10GWC |
| 800E | 0.2/0.5/5P20 | 15 | 15 | 20 | / | 20 | / | LZZBJ9-10GWC |
| 1000-2500E | 0.2/0.5/5P20 | 15 | 15 | 20 | / | 20 | / | LZZBJ9-10GWC |
| 0.2/0.5/5P20 | 15 | 15 | 20 | / | 20 | / | LZZBJ9-10GWC | |
| 1200-2500E | 0.2/0.5/5P20 | 20 | 20 | 20 | / | 20 | / | LZZBJ9-10GWC |
| 0.2/0.5/5P20 | 20 | 20 | 20 | / | 20 | / | LZZBJ9-10GWC | |
| 3000-4000E | 0.2/0.5/5P20 | 20 | 20 | 20 | / | 20 | / | LMZB3-10GWD |
| 0.2/0.5/5P20 | 20 | 20 | 20 | / | 20 | / | LMZB3-10GWE |
Dimension & outline drawing of LMZB3-10GWD-E — click image to zoom / view original.
This is a 10kV indoor through-core current transformer using dry epoxy resin insulation, a construction that removes oil handling and supports busbar-type primary routing in medium voltage switchgear. The dual-winding architecture separates metering from protection duties, and the epoxy cast body is built for indoor busbar installation.
Accuracy classes 0.2S, 0.5, 5P20 and 5P30 are available with rated burdens of 10VA, 15VA and 20VA, at 50/60Hz. The insulation level is 12/42/75kV, and the unit is designed to IEC 61869 and GB/T 20840. For the 3000-4000E primary current range, the 0.2/0.5/5P20 combination provides 20VA on each of those classes. Short-time thermal and dynamic withstand figures are [On Request].
Because it is an indoor device, deployment belongs in medium voltage switchgear busbar compartments, including heavy industrial distribution in metallurgy, mining, cement and chemical plants. Never open-circuit the secondary while energized. Earth the secondary at one point and follow the nameplate terminal diagram. Ratio, accuracy class and winding configuration can be customized, with documentation and test evidence supplied on request.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1200A、1500A、2000-6000A; multiple accuracy combinations like 0.2S/0.5S、0.2S/10P15、10P15/10P15、0.5S/10P15, rated output values 15VA/20VA/30VA for different grades, net weight 30kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000-3000A、4000-6000A; accuracy combinations including 0.2S/0.2S、0.2S/0.5S、0.2S/10P15/10P15、0.5S/10P15/10P15, rated output values 15VA/20VA/30VA corresponding to different accuracy grades, net weight 45kg, ambient operating temperature -5℃~+40℃.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.