Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1200A、1500A、2000-6000A; multiple accuracy combinations like 0.2S/0.5S、0.2S/10P15、10P15/10P15、0.5S/10P15, rated output values 15VA/20VA/30VA for different grades, net weight 30kg, ambient operating temperature -5℃~+40℃.
Indoor 10kV current transformer for medium voltage switchgear, suitable for metering and protection up to 6000A.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LMZB3-10Q | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary busbar through the hollow window. Secondary terminals: 1S1/1S2 for metering winding, 2S1/2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q: What are the available accuracy classes?
A: Available accuracy combinations include 0.2S/0.5S, 0.2S/10P15, 10P15/10P15, and 0.5S/10P15.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current I1n (A) | Accuracy classCombined | 0.2(S) | 0.5(S) | 10P15 | Weight (kg) |
|---|---|---|---|---|---|---|
| LMZB3-10(Q) | 1000-1200 | 0.2(S)/0.5(S) | 15 | 15 | 15 | 30 |
| LMZB3-10(Q) | 1500 | 0.2(S)/0.5(S) | 20 | 20 | 20 | 30 |
| LMZB3-10(Q) | 2000-6000 | 0.2(S)/0.5(S) 10P15/10P15 0.5(S)/10P15 | 30 | 30 | 30 | 30 |
| LMZB3-10G | 1000-1500 | 0.2(S)/0.5(S) | 15 | 15 | 15 | 45 |
| LMZB3-10G | 2000-3000 | 0.2(S)/0.5(S) | 20 | 20 | 20 | 45 |
| LMZB3-10G | 4000-6000 | 0.2(S)/10P15/10P15 0.5(S)/10P15/10P15 | 30 | 30 | 30 | 45 |
Dimension & outline drawing of LMZB3-10Q — click image to zoom / view original.
The LMZB3-10Q is a 10 kV indoor single-phase epoxy resin cast current transformer, intended for revenue metering and protection on 50/60 Hz systems where accuracy directly affects billing settlement. Its 0.2(S) and 0.5(S) classes support metering, with 10P15 protection cores available in the same unit.
The hollow bushing design carries the primary conductor through the core, and the equal potential line construction distributes the electric field within the dry epoxy body. Metering and protection windings are configured together, with rated outputs of 15 VA or 30 VA depending on the primary current selected from 1000-1200 A, 1500 A or 2000-6000 A. Insulation level is 12/42/75 kV, and the unit weighs 30 kg.
This is an indoor device for ambient temperatures of -5℃ to +40℃, suited to switchgear metering and protection circuits; it is not intended for direct current or non-standard frequencies. Never open-circuit the secondary while the primary is energized. Earth the secondary at one point and follow the nameplate terminal diagram. Ratio and accuracy-class combinations, documentation and delivery terms are available on request.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000-3000A、4000-6000A; accuracy combinations including 0.2S/0.2S、0.2S/0.5S、0.2S/10P15/10P15、0.5S/10P15/10P15, rated output values 15VA/20VA/30VA corresponding to different accuracy grades, net weight 45kg, ambient operating temperature -5℃~+40℃.
10kV Indoor Through-Core Epoxy Cast Current Transformer
LMZB3-10GWD,E 10kV Indoor Through-Core Epoxy Cast Current Transformer (LMZB3-10GWD-E) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.