Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000-3000A、4000-6000A; accuracy combinations including 0.2S/0.2S、0.2S/0.5S、0.2S/10P15/10P15、0.5S/10P15/10P15, rated output values 15VA/20VA/30VA corresponding to different accuracy grades, net weight 45kg, ambient operating temperature -5℃~+40℃.
Indoor 10kV cast-resin current transformer for medium-voltage switchgear, suitable for metering and protection in 12kV systems.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LMZB3-10G | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: 12kV system; power-frequency withstand 42kV; lightning impulse withstand 75kV peak.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only.
Q: What secondary currents are available?
A: 5A or 1A.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current I1n (A) | Accuracy classCombined | 0.2(S) | 0.5(S) | 10P15 | Weight (kg) |
|---|---|---|---|---|---|---|
| LMZB3-10(Q) | 1000-1200 | 0.2(S)/0.5(S) | 15 | 15 | 15 | 30 |
| LMZB3-10(Q) | 1500 | 0.2(S)/0.5(S) | 20 | 20 | 20 | 30 |
| LMZB3-10(Q) | 2000-6000 | 0.2(S)/0.5(S) 0.5(S)/10P15 10P15/10P15 | 30 | 30 | 30 | 30 |
| LMZB3-10G | 1000-1500 | 0.2(S)/0.5(S) | 15 | 15 | 15 | 45 |
| LMZB3-10G | 2000-3000 | 0.2(S)/0.5(S) | 20 | 20 | 20 | 45 |
| LMZB3-10G | 4000-6000 | 0.2(S)/10P15 0.5(S)/10P15 0.5(S)/10P15/10P15 | 30 | 30 | 30 | 45 |
Dimension & outline drawing of LMZB3-10G — click image to zoom / view original.
The LMZB3-10G is a 10kV indoor single-phase epoxy resin cast current transformer, used in medium-voltage switchgear to step primary current down to a 5A/1A secondary for metering and protection. Its through-core construction uses a cast epoxy body with an integrated shielding layer, giving dry insulation rated 12/42/75kV for 50/60Hz systems. The unit weighs 45kg.
Accuracy is 0.2(S), with rated outputs of 15VA, 20VA or 30VA depending on the primary current range of 1000-1500A, 2000-3000A or 4000-6000A respectively; the secondary burden should be matched to the stated VA window. As a single-core metering-and-protection CT, it suits applications where one core covers both duties, rather than dual-core or residual-voltage designs. Compliance follows the IEC 61869 series, with routine and type test documentation available [On Request].
Typical deployment is in indoor substation bays for busbar current measurement and protection. Earth the secondary at one point and never open-circuit it while energized. It is not intended for DC or non-standard frequencies. OEM branding and document packages can be discussed; ambient range is -5℃ to +40℃.
Same product family, different ratings — compare before you specify.
10kV Indoor Through-Core Epoxy Cast Current Transformer
LMZB3-10GWD,E 10kV Indoor Through-Core Epoxy Cast Current Transformer (LMZB3-10GWD-E) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1200A、1500A、2000-6000A; multiple accuracy combinations like 0.2S/0.5S、0.2S/10P15、10P15/10P15、0.5S/10P15, rated output values 15VA/20VA/30VA for different grades, net weight 30kg, ambient operating temperature -5℃~+40℃.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.