KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZK-10PU
LMZK-10PU Indoor Open-Core Self-Powered Current Transformer
10kVLMZK-10PU
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2): (0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P))
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZK-10PU

LMZK-10PU Indoor Open-Core Self-Powered Current Transformer

LMZK-10PU Indoor Open-Core Self-Powered Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P), rated burden 20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P). Design: insulation level 18/55/105kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Key Engineering Advantages

  • Self-powered open-core CT
  • built-in power winding for passive microcomputer protection devices
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZK-10PU

Electrical Parameters

Primary Rated Voltage (Un):10kV
Metering & Protection Class:0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P)
Rated Output Burden:20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P)
Rated Frequency:50Hz / 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):18/55/105kV
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LMZK-10PU is a self-powered open-core CT for indoor RMU applications, providing protection and metering with a built-in power winding. It suits 15kV systems with insulation level 18/55/105kV.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLMZK-10PUFactory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P)Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P)Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)18/55/105kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz / 60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor ring main units (RMU) and switchgear panels
  • Self-powered protection schemes for passive microcomputer relays
  • Metering and protection in 15kV distribution networks
  • Applications requiring accuracy classes 0.2/3P, 0.5/3P, or 1.0/3P

Not Recommended For

  • Outdoor substations or exposed installations
  • Gas-insulated switchgear (GIS) due to open-core design
  • High-voltage transmission systems above 15kV
  • Applications requiring high short-circuit withstand capability

Topology & Wiring

Connect primary conductor through the open core. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. The power supply winding terminals are [On Request]. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of LMZK-10PU?

A: The insulation level is 18/55/105kV, meaning 18kV system voltage, power-frequency withstand 55kV, lightning impulse withstand 105kV peak.

Q: How does the self-powered feature work?

A: The built-in power winding generates energy from primary current to power passive protection devices, operating when primary current exceeds 10% of rated.

Q: What accuracy classes are available?

A: Accuracy classes include 0.2/3P, 0.5/3P, and 1.0/3P, with corresponding rated burdens up to 120VA.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZK-10PU
5 cols · 5 rows

LMZK-10PU Self-powered Current Transformer — Technical Data

ModelRated primary current I1n (A)Accuracy class & rated output (VA) COSφ=0.8 Protection winding10P10Accuracy class & rated output (VA) COSφ=0.8 Power supply windingDimensions Φd/ΦD/H
LMZK1250-10PU100/51550/124/100
LMZK1150-10PU200/51.5550/110/100
LMZK1150-10PU300/52.5550/110/100
LMZK1150-10PU400/53.75550/110/100
LMZK1150-10PU600/55550/110/100
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZK-10PU — click image to zoom / view original.

Product Overview

About This Product

LMZK-10PU

The LMZK-10PU is a 10 kV indoor open-core current transformer built around a dry epoxy resin insulation system, a construction choice that removes the liquid-handling and maintenance routines associated with oil-filled units and gives the winding assembly a solid, dimensionally stable body. The epoxy body also supports the unit's 18/55/105 kV insulation level, which defines its power-frequency and lightning-impulse withstand capability for this voltage class.

Accuracy classes 0.2/3P(6P), 0.5/3P(6P) and 1.0/3P(6P) are offered with rated burdens of 20VA(0.2), 75VA(0.5), 120VA(1.0) and 100VA(3P) at 50Hz or 60Hz. A built-in power winding supplies passive microcomputer protection devices, so the open-core design serves metering and protection duties in medium-voltage switchgear, ring-main units and centrally installed cubicles. Compliance follows the IEC 61869 series, with type-test evidence and documentation available [On Request].

This unit is for indoor service only; the secondary circuit must never be open-circuited while the primary is energized. Ratio and accuracy-class customization, sample support and delivery schedules are quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMZK-10 Indoor Open-Core Current Transformer for 10kV Ring Main Unit
10kV
Current Transformer50Hz / 60Hz

LMZK-10

Indoor Open-Core Current Transformer for 10kV Ring Main Unit

LMZK-10 Indoor Open-Core Current Transformer for 10kV Ring Main Unit is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P), rated burden 20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P). Design: insulation level 0.72/3kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P)
View Specs
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1765

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs