KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLSXZ
LSXZ Series 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker
12kVLSXZ
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 12kV
Secondary Metering (1S1 - 1S2):5A or 1A (0.2S, 0.5, 5P20, 5P30)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LSXZ

LSXZ Series 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker

Three-phase and zero-sequence integrated combination current transformer. Suitable for installation in outdoor circuit breakers or ring main units. Used for three-phase and zero-sequence current measurement and protection. Also applicable for zero-sequence current protection of multi-cable circuits. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, compact design, easy installation. Integrated three-phase + zero-sequence function saves space and cost.

Key Engineering Advantages

  • Three-phase + zero-sequence integrated CT
  • outdoor pole-mounted
  • epoxy cast
  • IEC compliant
  • combined measurement & protection
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LSXZ

Electrical Parameters

Primary Rated Voltage (Un):12kV
Secondary Winding Currents:5A or 1A
Metering & Protection Class:0.2S, 0.5, 5P20, 5P30
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Environmental Class:Indoor pillar-type epoxy resin cast
Standards Conformance:IEC 61869, GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

KYN28 medium voltage switchgear
GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LSXZ is a 12kV outdoor three-phase integrated CT with zero-sequence, ideal for pole-mounted circuit breakers and RMUs.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869, GB/T 20840
Model CodeLSXZFactory nameplate marking
Primary Voltage12kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class0.2S, 0.5, 5P20, 5P30Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
StandardsIEC 61869, GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentIndoor pillar-type epoxy resin castPer datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 12kV outdoor pole-mounted circuit breakers
  • Ring main units (RMUs) requiring three-phase and zero-sequence CTs
  • Zero-sequence current protection for multi-cable circuits
  • Medium voltage switchgear (e.g., KYN28) with combined measurement and protection needs

Not Recommended For

  • Indoor applications (designed for outdoor use)
  • Systems above 12kV (e.g., 24kV or 36kV)
  • Gas-insulated switchgear (GIS) due to construction type
  • High-accuracy revenue metering requiring class 0.1 or 0.2 (only 0.2S available)

Topology & Wiring

secondary terminals 1S1/1S2 for measurement, 2S1/2S2 for protection (if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. For zero-sequence CT, ensure proper polarity and grounding per IEC 61869.

Standards & Compliance

Compliant with: IEC 61869, GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of LSXZ?

A: 12kV system; power-frequency withstand 42kV; lightning impulse withstand 75kV peak.

Q: Can LSXZ be used indoors?

A: No, it is designed for outdoor pole-mounted applications.

Q: What accuracy classes are available?

A: 0.2S, 0.5, 5P20, and 5P30.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LSXZ
2 cols · 8 rows

LS (X)Z SeriesThree-Phase (Zero-Sequence )Integrated Combined Current Transformer — Technical Data

ParameterValue
Product performance complies with standardsGB/T20840.1, 2 and IEC61869-1, 2 standards
Rated voltage0.72/3kV
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Ambient temperature-40℃~+60℃
AltitudeNot exceeding 3000m
Pollution degreeClass II
Rated continuous thermal current120%~120% In
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LSXZ — click image to zoom / view original.

Product Overview

About This Product

LSXZ

This is a 12 kV outdoor three-phase integrated current transformer with a zero-sequence core, intended to measure and protect pole-mounted circuit breakers on medium-voltage distribution lines. Its dry epoxy resin cast insulation, rated 12/42/75 kV, forms the solid dielectric body that houses the phase and zero-sequence windings in one unit.

The windings are encapsulated by vacuum casting or automatic pressure gelation, producing a void-free solid insulation structure. Accuracy classes 0.2S, 0.5, 5P20 and 5P30 cover both metering and protection, with secondary outputs of 5 A or 1 A at 50/60 Hz. The rated continuous thermal current is 120% In, and short-time thermal and dynamic withstand figures are available in the datasheet. Standard stocked ratios suit routine switchgear; non-standard ratios and class combinations are built to order.

Compliance follows IEC 61869 and GB/T 20840, supported by datasheets, outline drawings and test reports. Typical deployment is KYN28 medium-voltage switchgear. Observe primary P1/P2 polarity and mount according to the outline drawing; earth the secondary at one point and never open-circuit it while energized. The secondary must never be open-circuited under load. [On Request] for weight and specific short-time ratings.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs