中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLXK-120TH
LXK-Φ120TH Split-Core Zero Sequence Current Transformer for Earth Fault Protection
Up to 35kVLXK-120TH
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — Up to 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LXK-120TH

LXK-Φ120TH Split-Core Zero Sequence Current Transformer for Earth Fault Protection

Waterproof zero sequence current transformer, model LXK-Φ120TH. Excellent waterproof performance for humid indoor environments. Rated up to 35kV, 50/60Hz. Split design with waterproof sealing ring, hot-line installation. TH tropicalized design, compliant with IEC 61869 standards. Used for three-phase cable ground fault protection.

Key Engineering Advantages

  • Waterproof zero sequence CT
  • Φ120
  • TH tropicalized
  • split design with sealing ring
  • humid environment suitable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LXK-120TH

Electrical Parameters

Primary Rated Voltage (Un):Up to 35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869, GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

Humid indoor environment ground protection
GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Split-core zero sequence CT for earth fault protection, rated up to 35kV, with waterproof and tropicalized design for humid indoor environments.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869, GB/T 20840
Model CodeLXK-120THFactory nameplate marking
Primary VoltageUp to 35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869, GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Ground fault protection in three-phase cable systems
  • Humid indoor environments (waterproof, tropicalized)
  • Retrofit installation on existing cables (split-core, hot-line)
  • Systems up to 35kV, 50/60Hz

Not Recommended For

  • Outdoor installations (not specified for outdoor use)
  • High-accuracy metering (zero sequence CT, not for revenue metering)
  • Non-ferrous or busbar applications (designed for cable, Φ120)
  • Environments with extreme temperatures (not specified)

Topology & Wiring

secondary terminals 1S1/1S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Connect the secondary to a protective relay or earth fault detection device. Ensure the primary cable passes through the center and the split core is properly closed and sealed.

Standards & Compliance

Compliant with: IEC 61869, GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the maximum system voltage for this CT?

A: Up to 35kV.

Q: Can it be installed without de-energizing the cable?

A: Yes, it is a split-core design with hot-line installation capability.

Q: Is it suitable for outdoor use?

A: It is designed for humid indoor environments; outdoor use is not specified.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LXK-120TH
4 cols · 10 rows

LXK-Φ120TH Waterproof Zero-Sequence Current Transformer

ModelRated primary current (A)Accuracy classRated output (VA)
LXK-Φ120TH50-75/110P101.5
LXK-Φ120TH100/110P103.75
LXK-Φ120TH150/110P102.5
LXK-Φ120TH200-300/110P103.75
LXK-Φ120TH400-600/110P105
LXK-Φ120TH100/510P102.5
LXK-Φ120TH150-200/510P102.5
LXK-Φ120TH300-400/510P103.75
LXK-Φ120TH500/510P105
LXK-Φ120TH600/510P105
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LXK-120TH — click image to zoom / view original.

Product Overview

About This Product

LXK-120TH

The LXK-120TH is a split-core zero sequence current transformer for earth fault protection on systems up to 35kV, built and tested to IEC 61869 and GB/T 20840. Its dry epoxy resin insulation and split-core construction with sealing ring suit humid indoor environments, where the tropicalized TH finish helps the unit tolerate damp switchgear rooms.

Accuracy class 10P10 is held across the burden range, with rated outputs from 1.5VA to 5VA depending on the selected ratio, covering 50-75/1 through 600/1 and 100/5 through 600/5. The 10P10 class supports consistent error performance from light load toward full burden. Because this is a current transformer, the secondary must never be open-circuited while the primary is energized; short the secondary before breaking the circuit.

This unit is for indoor service only and must not be installed in outdoor exposed locations. Earth the secondary at one point and follow the nameplate terminal diagram. For ratio or accuracy customization, documentation packages and lead times, contact the factory; [On Request] details are available on inquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LXK Φ80 to Φ240 Zero Sequence Current Transformer for Earth Fault Protection
Up to 35kV
Current Transformer50/60Hz

LXK80-240

LXK Φ80 to Φ240 Zero Sequence Current Transformer for Earth Fault Protection

Indoor zero sequence current transformer for 35kV and below systems. Used for three-phase cable ground protection in small grounding current systems. Can also be used with relay protection devices. Rated frequency 50Hz or 60Hz. Available in Φ80 to Φ240 inner diameter sizes. Split design with clamp fastening, can be installed without power interruption. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, suitable for indoor installation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1765

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs