Zero sequence current transformer for low voltage systems, rated 0.72/3kV. Rectangular through-core design for cable installation. Rated frequency 50/60Hz, secondary current 5A or 1A. Ambient temperature range -40°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Used for ground fault protection and residual current monitoring. Epoxy resin cast, reliable performance, easy installation.
LXZ is a zero-sequence current transformer for 0.72/3kV systems, ideal for ground fault protection and residual current monitoring in low-voltage networks.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LXZ | Factory nameplate marking |
| Primary Voltage | 0.72/3kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Rectangular through-core epoxy cast; Ambient: -40°C ~ +40°C | Per datasheet limits |
Ideal For
Not Recommended For
Connect secondary terminals 1S1 and 1S2 to the protection relay. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure the primary conductor passes through the rectangular window and is properly insulated.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating of the LXZ?
A: The primary voltage rating is 0.72/3kV.
Q: What are the available secondary current ratings?
A: The secondary current is available in 5A or 1A.
Q: What standards does the LXZ comply with?
A: It complies with IEC 61869 and GB/T 20840.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 |
| Rated voltage | 0.72/3kV |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Ambient temperature | -40℃~+40℃ |
Dimension & outline drawing of LXZ — click image to zoom / view original.
When residual ground-fault current is too small for a conventional phase CT to resolve, this LXZ series unit provides the dedicated zero-sequence measurement channel that ground-fault protection and residual current monitoring depend on. It is a 0.72/3kV current transformer with a rectangular through-core, intended for the 50Hz or 60Hz circuits of the stated ambient range of -40°C to +40°C.
The insulation is dry epoxy resin, cast around the core and windings to form a rectangular aperture that primary conductors pass through; the secondary delivers 5A or 1A. Accuracy class and rated output in VA are stated on the nameplate and in the official datasheet, as is the insulation level. The design follows GB/T20840.1 and GB/T20840.2 and IEC61869-1 and IEC61869-2, and type-test evidence is available [On Request].
Deployment is in medium-voltage switchgear and ring-main units, where the rectangular core fits around the cable or busbar. Earth the secondary at one point and never open-circuit it while energized; verify wiring before energization. DC and non-standard frequencies are outside its scope. Ratio and accuracy customization, sample and type-test support, and documentation packages are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.