中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLXZ
LXZ Series 10kV Three-Phase Integrated Current Transformer with Zero-Sequence Winding
0.72/3kVLXZ
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.72/3kV
Secondary Metering (1S1 - 1S2):5A or 1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LXZ

LXZ Series 10kV Three-Phase Integrated Current Transformer with Zero-Sequence Winding

Zero sequence current transformer for low voltage systems, rated 0.72/3kV. Rectangular through-core design for cable installation. Rated frequency 50/60Hz, secondary current 5A or 1A. Ambient temperature range -40°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Used for ground fault protection and residual current monitoring. Epoxy resin cast, reliable performance, easy installation.

Key Engineering Advantages

  • 0.72/3kV zero sequence CT
  • rectangular through-core
  • epoxy cast
  • ground fault protection
  • IEC compliant
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LXZ

Electrical Parameters

Primary Rated Voltage (Un):0.72/3kV
Secondary Winding Currents:5A or 1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Environmental Class:Rectangular through-core epoxy cast; Ambient: -40°C ~ +40°C
Standards Conformance:IEC 61869, GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

Ground fault protection
residual current monitoring
GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LXZ is a zero-sequence current transformer for 0.72/3kV systems, ideal for ground fault protection and residual current monitoring in low-voltage networks.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869, GB/T 20840
Model CodeLXZFactory nameplate marking
Primary Voltage0.72/3kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869, GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentRectangular through-core epoxy cast; Ambient: -40°C ~ +40°CPer datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Ground fault protection in low-voltage systems
  • Residual current monitoring
  • Cable installations with rectangular through-core design
  • Indoor and outdoor applications within -40°C to +40°C

Not Recommended For

  • High-voltage transmission systems above 3kV
  • Revenue metering requiring high accuracy
  • Protection schemes requiring multiple secondary windings

Topology & Wiring

Connect secondary terminals 1S1 and 1S2 to the protection relay. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure the primary conductor passes through the rectangular window and is properly insulated.

Standards & Compliance

Compliant with: IEC 61869, GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating of the LXZ?

A: The primary voltage rating is 0.72/3kV.

Q: What are the available secondary current ratings?

A: The secondary current is available in 5A or 1A.

Q: What standards does the LXZ comply with?

A: It complies with IEC 61869 and GB/T 20840.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LXZ
2 cols · 5 rows

LXZ Zero-Sequence Current Transformer — Technical Data

ParameterValue
Product performance complies with standardsGB/T20840.1, 2 and IEC61869-1, 2
Rated voltage0.72/3kV
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Ambient temperature-40℃~+40℃
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LXZ — click image to zoom / view original.

Product Overview

About This Product

LXZ

When residual ground-fault current is too small for a conventional phase CT to resolve, this LXZ series unit provides the dedicated zero-sequence measurement channel that ground-fault protection and residual current monitoring depend on. It is a 0.72/3kV current transformer with a rectangular through-core, intended for the 50Hz or 60Hz circuits of the stated ambient range of -40°C to +40°C.

The insulation is dry epoxy resin, cast around the core and windings to form a rectangular aperture that primary conductors pass through; the secondary delivers 5A or 1A. Accuracy class and rated output in VA are stated on the nameplate and in the official datasheet, as is the insulation level. The design follows GB/T20840.1 and GB/T20840.2 and IEC61869-1 and IEC61869-2, and type-test evidence is available [On Request].

Deployment is in medium-voltage switchgear and ring-main units, where the rectangular core fits around the cable or busbar. Earth the secondary at one point and never open-circuit it while energized; verify wiring before energization. DC and non-standard frequencies are outside its scope. Ratio and accuracy customization, sample and type-test support, and documentation packages are quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs