LZFT-10 Indoor Square Bushing-Type High-Precision Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.
LZFT-10 is a 35kV indoor current transformer for 10kV ring main units, offering high precision and dry epoxy insulation. Suitable for metering and protection in RMU applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZFT-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers, observe polarity: primary P1/P2, secondary S1/S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating of the LZFT-10?
A: The primary voltage is 35kV, but it is designed for 10kV ring main units.
Q: Is the LZFT-10 suitable for outdoor use?
A: No, it is an indoor type with dry epoxy insulation, intended for indoor RMU installations.
Q: What standards does the LZFT-10 comply with?
A: It complies with GB/T20840.1/2 and IEC61869-1/2 standards.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 |
| Rated insulation level | 0.72/3kV |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Ambient temperature | -5℃~+40℃ |
Dimension & outline drawing of LZFT-10 — click image to zoom / view original.
The LZFT-10 is an indoor, square bushing-type current transformer for 10kV systems, designed to step primary current down to a metered or protective secondary level in ring main cabinet installations. Its performance follows GB/T20840.1 and .2 and IEC61869-1 and .2, so the unit can be specified against the standard framework familiar to protection and metering engineers.
The insulation is dry epoxy resin, cast to form a solid, void-free body around the windings. The rated insulation level is 0.72/3kV, the rated frequency is 50Hz or 60Hz, and the rated secondary current is 5A or 1A. Accuracy class, rated output in VA and short-time thermal ratings are stated on the nameplate and the official datasheet [On Request].
Typical deployment is indoor 10kV ring main cabinets in wind, photovoltaic and storage collector stations, where the square bushing format fits the cabinet geometry. Before energizing, verify the secondary burden in VA against the connected relays and meters, earth the secondary at one point, and never open-circuit the secondary while the primary is energized. Ratio and accuracy-class variants, OEM marking and the test-report package are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.