LZJC-10G Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor 10kV epoxy cast current transformer for MV switchgear, suitable for metering and protection with dual accuracy windings.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LZJC-10G | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary in series with the line. Secondary terminals: 1S1/1S2 for metering winding, 2S1/2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal markings.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV highest voltage for equipment, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q: What accuracy classes are available?
A: Available accuracy combinations include 0.2S/10P15 and 0.5S/10P15, with rated outputs of 10VA for metering and 15VA for protection.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only. For outdoor applications, a suitable enclosure or a different product is required.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current I1n (A) | Accuracy classCombined | 0.2(S) | 0.5(S) | 10P10 | 10P15 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| LZJ-10G | 20-400 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJ-10G | 500-600 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJ-10G | 800 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJ-10G | 1000 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 20-400 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 500-600 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 800 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 1000 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
Dimension & outline drawing of LZJC-10G — click image to zoom / view original.
Built to the IEC 61869 and GB/T 20840 standards, this LZJC-10G is a 10 kV indoor single-phase current transformer that steps primary current down to a 5 A or 1 A secondary for metering and protection in medium-voltage switchgear.
Its dry epoxy resin body provides solid insulation, and the casting process is carried out to exclude voids from the insulation. The unit weighs 15 kg. Accuracy classes 0.2, 0.5 and 1.0 are available, with 10P15 protection windings and rated outputs of 10 VA or 15 VA depending on the class combination. Short-time thermal current is 60 I1n and rated dynamic current 120 I1n.
Because it is an indoor device, it belongs in substation bays and busbar metering and protection panels, not in outdoor yards. Earth the secondary at one point and never open-circuit it while energized. Calibration certificates for revenue metering are available [On Request]. Over-specifying a higher accuracy class than the application needs adds cost without benefit. Ratio and class options, export packing and after-sales support are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.