LZJD-10G Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor 10kV epoxy cast current transformer for MV switchgear, rated 0.66kV primary, 5A secondary, accuracy 0.2S.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LZJD-10G | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary terminals in series with the line. Secondary terminals: 1S1/1S2 for metering winding, 2S1/2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal markings.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q: Can this CT be used for outdoor applications?
A: No, it is designed for indoor use only.
Q: What are the available primary current ranges?
A: Optional primary current ranges: 20-400A, 500-600A, 800A, 1000A.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current I1n (A) | Accuracy classCombined | 0.2(S) | 0.5(S) | 10P10 | 10P15 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| LZJ-10G | 20-400 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJ-10G | 500-600 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJ-10G | 800 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJ-10G | 1000 | 0.2(S)/10P10 0.5(S)/10P10 | 10 | 10 | 15 | — | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 20-400 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 500-600 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 800 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
| LZJC-10G LZJD-10G | 1000 | 0.2(S)/10P15 0.5(S)/10P15 | 10 | 10 | — | 15 | 60 I1n | 120 I1n | 15 |
Dimension & outline drawing of LZJD-10G — click image to zoom / view original.
This LZJD-10G is a 10 kV indoor single-phase epoxy resin cast current transformer, designed to step primary current down to a 5 A secondary for metering and control in medium-voltage switchgear. It is typically installed in KYN28-type cubicles, ring main units and substation bays where a compact, dry-type CT is required.
The epoxy resin cast body provides the primary insulation and also fixes the winding geometry, which helps keep the unit compact enough for restricted panel space. The dual-functional winding design supports both measurement and protection duties from one housing. The accuracy class is 0.2S at 50/60 Hz, and the unit weighs 15 kg. Short-time thermal and dynamic current ratings, along with the protection-core ALF, are stated on the nameplate and in the official datasheet rather than repeated here.
Compliance follows IEC 61869 and GB/T 20840; routine and type test evidence, including [On Request] documentation, is available with the quotation. The secondary must never be open-circuited while the primary is energized. Before commissioning, carry out insulation resistance, polarity and ratio checks. Ratio and accuracy-class combinations are customized per order, with the file package and delivery schedule confirmed at inquiry.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.