KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZYT-10
LZYT-10 Indoor Bushing-Type High-Precision Current Transformer
27.5kVLZYT-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 27.5kV
Secondary Metering (1S1 - 1S2): (0.2、0.5)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZYT-10

LZYT-10 Indoor Bushing-Type High-Precision Current Transformer

Indoor single-phase circular bushing-type current transformer matched for 10kV ring main units, complying with GB/T20840.1/2 and IEC61869-1/2 standards.

Key Engineering Advantages

  • Circular bushing-type precision current transformer specially designed for 10kV ring main cabinet matching installation
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZYT-10

Electrical Parameters

Primary Rated Voltage (Un):27.5kV
Metering & Protection Class:0.2、0.5
Rated Output Burden:20VA(0.2),50VA(0.5),100VA(1.0),200VA(3P)
Rated Frequency:50Hz / 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):31.5/95/200kV
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 27.5kV bushing-type CT for ring main units; accuracy 0.2/0.5, burden up to 200VA. Suitable for protection and metering in RMU applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZYT-10Factory nameplate marking
Primary Voltage27.5kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class0.2、0.5Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden20VA(0.2),50VA(0.5),100VA(1.0),200VA(3P)Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)31.5/95/200kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz / 60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 10kV ring main unit (RMU) applications
  • Indoor switchgear installations
  • Current measurement and protection in MV networks
  • Metering and relay protection with accuracy classes 0.2/0.5

Not Recommended For

  • Outdoor substations
  • Gas-insulated switchgear (GIS) without adapter
  • Voltage transformation (PT) applications
  • High-voltage systems above 27.5kV

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal conventions.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The insulation level is 27.5kV system; power-frequency withstand 95kV; lightning impulse withstand 200kV peak.

Q: What accuracy classes are available?

A: Accuracy classes 0.2 and 0.5 are available, with rated burdens of 20VA and 50VA respectively.

Q: Is this CT suitable for outdoor use?

A: No, it is designed for indoor ring main units and should not be used outdoors.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZYT-10
2 cols · 5 rows

LZYT-10 Series Current Transformer — Technical Data

ParameterValue
Product performance complies with standardsGB/T20840.1, 2 and IEC61869-1, 2
Rated insulation level0.72/3kV
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Ambient temperature-5℃~+40℃
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZYT-10 — click image to zoom / view original.

Product Overview

About This Product

LZYT-10

The LZYT-10 is an indoor bushing-type current transformer for 10kV ring main cabinet matching installation, addressing the common pain of limited cabinet space and light-load metering deviation in compact switchgear. Its dry epoxy resin insulation and circular bushing construction keep the unit compact, so it occupies minimal panel volume and simplifies distribution room layout.

Accuracy classes 0.2 and 0.5 are offered with rated outputs of 20VA (0.2) and 50VA (0.5); the parameter table also lists 100VA (1.0) and 200VA (3P) burdens, a 5A or 1A secondary current, and a rated insulation level of 31.5/95/200kV. The protection-grade core is intended to resist saturation under fault currents, with the actual ALF/FS to be confirmed on the nameplate or official datasheet. Performance follows GB/T20840.1, 2 and IEC61869-1, 2, supported by datasheets, outline drawings and test reports.

This indoor unit suits infrastructure such as rail transit, data centres, hospitals and water utilities. Earth the secondary at one point and never open-circuit it while energized. It is not intended for DC or non-standard frequencies; [On Request] for custom ratios and OEM documentation packages.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs