Indoor single-phase circular bushing-type current transformer matched for 10kV ring main units, complying with GB/T20840.1/2 and IEC61869-1/2 standards.
Indoor 27.5kV bushing-type CT for ring main units; accuracy 0.2/0.5, burden up to 200VA. Suitable for protection and metering in RMU applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZYT-10 | Factory nameplate marking |
| Primary Voltage | 27.5kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | 0.2、0.5 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 20VA(0.2),50VA(0.5),100VA(1.0),200VA(3P) | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 31.5/95/200kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50Hz / 60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 27.5kV system; power-frequency withstand 95kV; lightning impulse withstand 200kV peak.
Q: What accuracy classes are available?
A: Accuracy classes 0.2 and 0.5 are available, with rated burdens of 20VA and 50VA respectively.
Q: Is this CT suitable for outdoor use?
A: No, it is designed for indoor ring main units and should not be used outdoors.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 |
| Rated insulation level | 0.72/3kV |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Ambient temperature | -5℃~+40℃ |
Dimension & outline drawing of LZYT-10 — click image to zoom / view original.
The LZYT-10 is an indoor bushing-type current transformer for 10kV ring main cabinet matching installation, addressing the common pain of limited cabinet space and light-load metering deviation in compact switchgear. Its dry epoxy resin insulation and circular bushing construction keep the unit compact, so it occupies minimal panel volume and simplifies distribution room layout.
Accuracy classes 0.2 and 0.5 are offered with rated outputs of 20VA (0.2) and 50VA (0.5); the parameter table also lists 100VA (1.0) and 200VA (3P) burdens, a 5A or 1A secondary current, and a rated insulation level of 31.5/95/200kV. The protection-grade core is intended to resist saturation under fault currents, with the actual ALF/FS to be confirmed on the nameplate or official datasheet. Performance follows GB/T20840.1, 2 and IEC61869-1, 2, supported by datasheets, outline drawings and test reports.
This indoor unit suits infrastructure such as rail transit, data centres, hospitals and water utilities. Earth the secondary at one point and never open-circuit it while energized. It is not intended for DC or non-standard frequencies; [On Request] for custom ratios and OEM documentation packages.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.