Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2、IEC61869-1/2 and JB/T8510.1-2007 standards; rated insulation level 31.5/95/185kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 10-2000A; accuracy-class rated outputs range 10-60VA for grades 0.2S,0.5S,0.2,0.5,5P10,5P15,5P20; short-time thermal current ranges 15-100kA, rated dynamic stable current ranges 37.5-200kA; product weight:85kg; ambient operating temperature -5℃~+40℃.
LZZB-27.5 is a 27.5kV indoor epoxy cast current transformer, suitable for medium voltage switchgear applications. It is not for outdoor or high voltage transmission use.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZB-27.5 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary terminals in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding is present, use 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure correct polarity for metering and protection.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: What secondary currents are available?
A: The secondary current can be 5A or 1A.
Q: What accuracy classes are offered?
A: Accuracy classes include 0.2S, 0.5S, 0.2, 0.5, 5P10, 5P15, and 5P20.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA)COSφ=0.5 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 10-50 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 150 1in | 375 1in | 85 |
| 75 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 15 | 37.5 | 85 |
| 100 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 25 | 75 | 85 |
| 150 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 31.5 | 80 | 85 |
| 200-250 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 45 | 112.5 | 85 |
| 300-500 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 50 | 125 | 85 |
| 600-630 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 10 10 15 20 50 30 20 | 63 | 130 | 85 |
| 750-1000 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 15 15 20 30 60 40 30 | 80 | 180 | 85 |
| 1200-2000 | 0.2(S)/0.2(S) 0.2(S)/0.5(S) 0.2(S)/5P 0.5(S)/5P | 15 15 20 30 60 40 30 | 100 | 200 | 85 |
Dimension & outline drawing of LZZB-27.5 — click image to zoom / view original.
The LZZB-27.5 is a 27.5 kV indoor single-phase epoxy resin cast current transformer, typically installed in switchgear bays and ring-main compartments to step primary current down to 5 A or 1 A for metering and protection. Its dry epoxy body replaces oil or SF6 insulation, reducing maintenance and fire risk, while the casting and winding process is supported by routine factory checks including ratio and polarity verification and dielectric screening.
Accuracy classes span 0.2(S) and 0.5(S) metering and 5P protection, with rated outputs from 10 VA to 60 VA depending on class and ratio; short-time thermal current reaches 100 kA for 1 s and dynamic stability 200 kA at the higher ratios, with a weight of 85 kg. The design follows IEEE C57.13 practice, and type-test reports and routine test certificates are available [On Request].
It suits indoor distribution in metallurgical, mining, cement and chemical plants. Before energizing, verify secondary burden against the rated VA and earth the secondary at one point; never open-circuit the secondary while energized. This indoor unit is not for outdoor installation. Custom ratios, accuracy classes and sample or type-test support are quoted on request.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Cast Current Transformer 10kV
LZZB3-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZB8-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.