LZZB3-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor epoxy cast CT for 10kV systems; suitable for metering and protection in MV switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LZZB3-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through bushing; secondary terminals 1S1/1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal markings.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level?
A: 12kV system; power-frequency withstand 42kV; lightning impulse withstand 75kV peak.
Q: What accuracy classes are available?
A: 0.2S/0.5S/0.5/1.0 for metering, with 5P for protection.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) 0.2 (5) | Accuracy class & rated output (VA) 0.5 (5) | Accuracy class & rated output (VA) 5P10/5P15 | Short-time thermal current (kA/S) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 20 | 0.2(5)/0.2(5) | 15 | 15 | 15 | 100 | 250 | — |
| 300 | 0.2(5)/0.5(5) | 15 | 15 | 15 | 24 | 60 | — |
| 400 | 0.2(5)/0.5(5) | 15 | 15 | 15 | 30 | 75 | 15 |
| 500 | 0.2(5)/5P10 | 15 | 15 | 15 | 40 | 100 | — |
| 600-800 | 0.5(5)/5P10 | 15 | 15 | 15 | 48 | 120 | — |
Dimension & outline drawing of LZZB3-10 — click image to zoom / view original.
The LZZB3-10 is a 10 kV indoor single-phase epoxy cast current transformer, used to step primary current down to a 5 A secondary for metering and protection in medium-voltage systems. Its dry epoxy resin insulation is applied by vacuum casting or automatic pressure gelation, producing a solid, gap-free body that encloses the windings and core.
Accuracy classes 0.2S/0.5S/0.5/1.0 are available with a rated burden of 15 VA at 50/60 Hz. The parameter table lists short-time thermal currents from 24 kA to 100 kA and dynamic stability currents from 60 kA to 250 kA across the primary current range, with a weight of 21 kg. The unit complies with IEC 61869 and GB/T 20840, and test reports and routine documentation can be supplied [On Request].
It is intended for indoor medium-voltage switchgear, ring-main units and central switchgear. Before energizing, verify the secondary burden in VA against the rated output, earth the secondary at one point, and never open-circuit the secondary while the primary is energized. The secondary must not be short-circuited. Ratio and accuracy-class customization, OEM marking and document packages are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.