中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZB-J7-35-Q
LZZB(J)7-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZB-J7-35-Q
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZB-J7-35-Q

LZZB(J)7-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZB(J)7-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZB-J7-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer with two-winding & three-winding options
  • broad current range and reliable thermal/dynamic performance
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZB-J7-35-Q

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 35kV class current transformer for medium voltage switchgear; suitable for protection and metering in indoor applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZB-J7-35-QFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • Metering and protection applications up to 35kV
  • Epoxy resin insulated, suitable for dry environments
  • Two-winding and three-winding configurations for flexibility

Not Recommended For

  • Outdoor installations without additional enclosure
  • High voltage transmission systems above 35kV
  • Gas insulated switchgear (GIS) without adaptation
  • Environments with extreme temperatures outside -5°C to +40°C

Topology & Wiring

For current transformer: connect primary in series with the line. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal conventions.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The insulation level is 40.5kV system; power-frequency withstand 95kV; lightning impulse withstand 185kV peak.

Q: What are the available secondary currents?

A: Secondary current is 5A or 1A.

Q: Can this CT be used outdoors?

A: No, it is designed for indoor use only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZB-J7-35-Q
6 cols · 15 rows

LZZB (J)7-35 (Q) Series Current Transformer

Rated primary current I1n (A)Accuracy classCombinedRated secondary output (VA)Short-time thermal current Ith (kA)Rated dynamic current Idyn (kA)Weight (kg)
200.2/0.5(0.5)/0.5 0.5/0.5/0.5 0.2/0.5/0.5 0.2/0.5/0.515 15 251.33.2595
30——25—
40——37.5—
50——4.511.5—
75——615—
100——822.5—
150——1230—
200——1645—
300——2050—
400——2563—
500——3690—
600——40100—
800——50125—
1000-1500——63160—
1500-2000——80200—
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZB-J7-35-Q — click image to zoom / view original.

Product Overview

About This Product

LZZB-J7-35-Q

This 35 kV indoor single-phase current transformer is specified within the IEC 61869, GB/T 20840 and IEEE C57.13 framework, stepping primary current down to 5 A or 1 A for metering and protection in medium-voltage switchgear. Its dry epoxy resin body is vacuum cast to form a solid, air-gap-free insulation around the core and windings, available in two-winding or three-winding configurations.

Accuracy is 0.2(S) for metering and 10P10 for protection, with rated outputs of 15 VA and 25 VA; at 20 A primary the short-time thermal current is 1.3 kA and dynamic stability 3.25 kA, and the unit weighs 95 kg. Insulation level is 40.5/95/185 kV at 50/60 Hz, and the design suits indoor switchgear and ring-main units rather than fused outdoor schemes. Datasheets, outline drawings and routine test reports are available [On Request].

Primary connections follow the P1/P2 markings, with the secondary earthed at one point and the circuit never opened while energized; pre-energization checks follow the nameplate. DC or non-standard frequencies are not applicable, and ambient must stay within -5℃~+40℃. Ratio and accuracy combinations are customized to order, with documentation packages quoted on request. ⚠️ Safety: Never open-circuit the secondary of a CT while energized — hazardous voltage develops.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
10kV
Current Transformer50/60Hz

LZZBJ9-10

Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0/5P10/10P10/10P15
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet
10kV
Current Transformer50/60Hz

LZZBJ9-10GWA-B-C

10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet

LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.

Accuracy Class0.2S, 0.5, 5P20, 5P30
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-135b-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs