KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ18-35G3-175-CGIS
LZZBJ18-35G3-175-CGIS Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZBJ18-35G3-175-CGIS
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A or 1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ18-35G3-175-CGIS

LZZBJ18-35G3-175-CGIS Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ18-35G3-175-CGIS Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Key Engineering Advantages

  • High insulation level
  • multiple accuracy combinations
  • excellent thermal and dynamic current resistance performance
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ18-35G3-175-CGIS

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A or 1A
Rated Frequency:50Hz / 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy resin CT for 10kV systems, suitable for CGIS switchgear with metering and protection applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ18-35G3-175-CGISFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz / 60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 10kV indoor switchgear and CGIS panels
  • Revenue metering with accuracy class 0.2S or 0.5S
  • Protection applications with class 5P or 10P
  • 50Hz or 60Hz power systems

Not Recommended For

  • Outdoor installation without additional enclosure
  • Systems above 10kV (e.g., 35kV class)
  • Gas-insulated switchgear (GIS) without proper adaptation
  • DC applications

Topology & Wiring

Connect primary terminals P1/P2 in series with the line. Secondary terminals are 1S1/1S2 for metering winding, and 2S1/2S2 for protection winding if applicable. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The insulation level is 0.72/3kV, meaning 0.72kV system voltage and 3kV power-frequency withstand voltage.

Q: Can this CT be used for outdoor applications?

A: No, it is designed for indoor use only, typically in CGIS switchgear.

Q: What accuracy classes are available?

A: The CT offers multiple accuracy combinations, including metering classes (e.g., 0.2S, 0.5S) and protection classes (e.g., 5P, 10P).

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ18-35G3-175-CGIS
9 cols · 6 rows

LZZBJ18-35G3/175/CGIS Current Transformer

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) 2COSφ=0.5 (0.2/0.5S)Accuracy class & rated output (VA) 2COSφ=0.5 (0.5)Accuracy class & rated output (VA) 2COSφ=0.5 (5P10)Accuracy class & rated output (VA) 2COSφ=0.5 (5P15)Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
20-1500.2(5)/0.5(5)10151510100 I1n250 I1n30
2000.2(5)/5P 0.5(5)/5P10151510256330
3000.2(5)/5P 0.5(5)/5P1015151031.58030
400-6000.2(5)/5P 0.5(5)/5P1015151031.5/28030
800-16000.2(5)/5P 0.5(5)/5P1015151031.5/48030
2000-2500—1015151031.5/48030
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ18-35G3-175-CGIS — click image to zoom / view original.

Product Overview

About This Product

LZZBJ18-35G3-175-CGIS

This is an indoor single-phase epoxy resin cast current transformer for 35kV systems, used to step primary current down to a 5A or 1A secondary for metering and protection. The dry epoxy casting is the defining feature: it removes the liquid-insulation maintenance burden of oil-filled units and gives a compact, sealed body suited to switchgear and CGIS enclosures.

The LZZBJ18-35G3-175-CGIS carries an insulation level of 40.5/95/185kV at 50Hz or 60Hz. Accuracy combinations include 0.2(5)/0.5(5) and 0.2(5)/5P, with rated outputs of 10VA and 15VA at 2COSφ=0.5. Short-time thermal current reaches 31.5kA/4s with 80kA dynamic rating on the larger ratios; weight is 30kg. Compliance follows the GB/T 20840 series, with test certificates and drawings available [On Request].

Typical deployment is indoor switchgear in infrastructure such as rail, data centres, hospitals and water works. Earth the secondary at one point and never open-circuit it while energized. Specify only the accuracy class the application needs, since overspecification wastes budget. Ratio and accuracy combinations are customizable; consult the nameplate and datasheet for exact ratings.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs