LZZBJ21-12/148/2s 4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ21-12-148-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor 12kV current transformer for protection and metering, suitable for medium voltage switchgear panels.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZBJ21-12-148-2s-4s | Factory nameplate marking |
| Primary Voltage | 12kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: What are the available accuracy classes?
A: Accuracy combinations include 0.2S/0.2S, 0.2S/0.5S, 0.2S/510P, and 0.5S/510P.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined 2s | Accuracy classCombined 4s | Accuracy class & rated output (VA) COSφ=0.8 0.2 (S) | Accuracy class & rated output (VA) COSφ=0.8 0.5 | Accuracy class & rated output (VA) COSφ=0.8 5 (10)P10 | Accuracy class & rated output (VA) COSφ=0.8 5 (10)P20 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| 15~200 | — | — | — | — | — | — | 100 1In | 250 1In | 23/30 |
| 300 | 0.2(S)/0.2(S) | 0.2(S)/0.5(S) | 15 | 15 | 20 | 15 | 31.5 | 80 | 23/30 |
| 400 | 0.2(S)/5(10)P | 0.2(S)/5(10)P | 15 | 15 | 20 | 15 | 45 | 112.5 | 23/30 |
| 500~600 | 0.5(S)/5(10)P | 0.5(S)/5(10)P | 15 | 15 | 20 | 15 | 63 | 130 | 23/30 |
| 800-1250 | — | — | 15 | 15 | 20 | 15 | 80 | 160 | 23/30 |
Dimension & outline drawing of LZZBJ21-12-148-2s-4s — click image to zoom / view original.
This is a 12 kV indoor single-phase current transformer built on a dry epoxy resin casting, a construction that removes oil handling and limits the footprint inside switchgear. The compact cast body helps free panel space in distribution rooms where cubicle depth is fixed.
The unit is specified for 50/60 Hz service with a 5A/1A secondary and a 15VA rated burden, so secondary cabling and meter or relay loads should be checked against that window at the design stage. Accuracy classes span 0.2(S), 0.5(S) and 5(10)P10 or 5(10)P20 depending on the primary current ordered, with short-time thermal current from 31.5 kA and dynamic ratings up to 160 kA across the range. Insulation is rated 12/42/75kV, ambient -5℃~+40℃, weight 23/30 kg.
Typical indoor deployment covers rail, data centre, hospital and water infrastructure substations. Before energising, verify insulation resistance, polarity and ratio; earth the secondary at one point and never open-circuit it under load. This unit is limited to 12 kV indoor service and must not be applied above that class. Ratio and accuracy combinations, calibration certificates and documentation packages are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.