中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ60-10
LZZBJ60-10 Indoor Single-phase Epoxy Resin Casting Current Transformer
10kVLZZBJ60-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ60-10

LZZBJ60-10 Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:20-150A、200A、300A、400A、500A、600-800A、1000-1250A; accuracy combinations:0.2S/510P10、0.5S/510P10、0.2S/0.5S, corresponding rated output:10VA for 0.2S,10VA for 0.5S,15VA for 510P10; short-time thermal current 16–64 kAS, rated dynamic stable current 40–160 kA, net weight 16kg, ambient operating temperature -5℃~+40℃.

Key Engineering Advantages

  • 10kV pillar-type cast CT with wide current range
  • excellent dynamic thermal stability
  • weight 16kg
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ60-10

Electrical Parameters

Primary Rated Voltage (Un):10kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 10kV cast-resin current transformer for MV switchgear, offering high accuracy and thermal stability.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ60-10Factory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • Metering and protection applications up to 10kV
  • Revenue metering with 0.2S accuracy
  • Systems requiring high short-time thermal current (up to 64kA)
  • 50/60Hz networks

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) applications
  • DC systems
  • High voltage above 10kV
  • Environments outside -5°C to +40°C

Topology & Wiring

Connect primary in series with the line. Secondary terminals: 1S1-1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse withstand.

Q: Can this CT be used for both metering and protection?

A: Yes, it offers accuracy combinations like 0.2S/5P10, with separate secondary windings for metering and protection.

Q: What is the weight of this CT?

A: The net weight is 16kg.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ60-10
7 cols · 7 rows

LZZBJ60-10 Current Transformer — Technical Data

Rated primary current I1n (A)Accuracy classCombinedRated output (VA) COSφ=0.8 (0.2/0.5/5P)Rated output (VA) COSφ=0.8 (10P)Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
20-1500.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)1010100/1n250/1n16
2000.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)1010164016
3000.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)1010246016
4000.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)1010307516
5000.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)10104010016
600-8000.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)10104812016
1000-12500.2(5)/5(10)P10 0.5(5)/5(10)P10 0.2(5)/0.5(5)10106416016
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ60-10 — click image to zoom / view original.

Product Overview

About This Product

LZZBJ60-10

The LZZBJ60-10 is a 10 kV indoor single-phase current transformer designed for metering and protection duties in medium-voltage switchgear, and it is engineered against the IEC 61869, GB/T 20840 and IEEE C57.13 standard families. Its dry epoxy resin cast body and pillar-type format keep the footprint compact, which helps when cabinet space and switchroom layout are tight.

Accuracy classes of 0.2(S), 0.5(S) and 5(10)P10 are available with a rated burden of 10 VA, and the 20-150 A range carries short-time thermal current of 100/1n kA/S and dynamic stability of 250/1n kA. Insulation is rated 12/42/75kV at 50/60Hz, and the unit weighs 16kg. Unlike fuse-protected designs, this CT has no integral primary fuse, so protection coordination must be handled by the upstream scheme.

Deployment is indoor, in substation bays and busbar metering and protection circuits, within an ambient range of -5℃~+40℃. Earth the secondary at one point and equalise potential before energising; never open-circuit a secondary while the primary is live. DC or non-standard frequencies are not applicable. OEM branding and a routine test document package are available, with ratio and class options quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs