KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-24-220b-2s-4s
LZZBJ9-24/220b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
10kVLZZBJ9-24-220b-2s-4s
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-24-220b-2s-4s

LZZBJ9-24/220b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Two optional structures: 2s and 4s, primary current optional range 20-3150A. 2s model weight is 43kg with rated output 15-30VA at different accuracy grades; 4s model weight is 70kg with rated output 15-30VA at different accuracy grades; short-time thermal current ranges 31.5-100kA, rated dynamic stable current ranges 80-160kA; ambient operating temperature -5℃~+40℃.

Key Engineering Advantages

  • 24kV indoor epoxy cast current transformer with 2s/4s two optional structures
  • outstanding thermal and dynamic stability
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-24-220b-2s-4s

Electrical Parameters

Primary Rated Voltage (Un):10kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

24 kV two- or four-core epoxy-cast CT, 20–3150 A, 0.2(S)/0.5/5P10 at 15–30 VA, 43 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-24-220b-2s-4sFactory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear and panels
  • Metering and protection applications up to 24kV
  • Systems requiring high short-circuit withstand (up to 100kA/160kA)
  • 50/60Hz networks with ambient temps -5°C to +40°C

Not Recommended For

  • Outdoor installations (indoor type only)
  • Gas-insulated switchgear (GIS) without adapter
  • High-voltage transmission systems above 24kV
  • DC systems or non-sinusoidal waveforms

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the maximum ratio of the 24 kV 220b frame?

A: 3150 A, in the 1000–3150 A band, where the outputs are 20/20 VA or 30/30 VA.

Q: Why choose the 220b over the 180b?

A: For ratios above 2500 A or metering burdens above 20 VA, which exceed the 180b frame's published range.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-24-220b-2s-4s
6 cols · 5 rows

LZZBJ9-24/220b/2s (4s) Series Current Transformer

Rated primary current (A)Accuracy classCombinedAccuracy class & rated output (VA) COSφ=0.8Short-time thermal current (kA/S)Rated dynamic current (kA)Weight (kg)
20-2000.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10)15/15, 20/20, 20/20, 15/15150/1375/143
3000.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10)15/15, 20/20, 20/20, 15/1531.58043
400-5000.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10)15/15, 20/20, 20/20, 15/154511043
600-8000.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10)15/15, 20/20, 20/20, 15/156313043
1000-31500.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10)20/20, 30/30, 30/30, 20/2010016043
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-24-220b-2s-4s — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-24-220b-2s-4s

LZZBJ9-24/220b/2s(4s) is the heavier of the two 24 kV frames: 43 kg, two or four cores, and 20 A to 3150 A primary. It exists because the 180b frame stops at 2500 A and at 20 VA; above that the winding package and the terminal block need the larger casting.

Rated output is 15/15 VA, 20/20 VA and 30/30 VA depending on the core pairing and ratio band, with accuracy 0.2(S)/0.2(S), 0.2(S)/0.5, 0.2(S)/5P10 or 0.5/5P10. Short-time thermal current is 150 times primary at 20–200 A and an absolute 100 kA with a 160 kA dynamic rating at 1000–3150 A.

For a 24 kV project, the choice between 180b and 220b is usually made by the maximum ratio and the metering burden, not by fault level alone. If the ratio is 2500 A or below and 20 VA is enough, the 36 kg 180b is the lighter option; otherwise specify the 220b.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35-250b-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-250b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-35A Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35A

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35A Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35D1

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs