Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Two optional structures: 2s and 4s, primary current optional range 20-3150A. 2s model weight is 43kg with rated output 15-30VA at different accuracy grades; 4s model weight is 70kg with rated output 15-30VA at different accuracy grades; short-time thermal current ranges 31.5-100kA, rated dynamic stable current ranges 80-160kA; ambient operating temperature -5℃~+40℃.
24 kV two- or four-core epoxy-cast CT, 20–3150 A, 0.2(S)/0.5/5P10 at 15–30 VA, 43 kg.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZBJ9-24-220b-2s-4s | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the maximum ratio of the 24 kV 220b frame?
A: 3150 A, in the 1000–3150 A band, where the outputs are 20/20 VA or 30/30 VA.
Q: Why choose the 220b over the 180b?
A: For ratios above 2500 A or metering burdens above 20 VA, which exceed the 180b frame's published range.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 | Short-time thermal current (kA/S) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 20-200 | 0.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10) | 15/15, 20/20, 20/20, 15/15 | 150/1 | 375/1 | 43 |
| 300 | 0.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10) | 15/15, 20/20, 20/20, 15/15 | 31.5 | 80 | 43 |
| 400-500 | 0.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10) | 15/15, 20/20, 20/20, 15/15 | 45 | 110 | 43 |
| 600-800 | 0.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10) | 15/15, 20/20, 20/20, 15/15 | 63 | 130 | 43 |
| 1000-3150 | 0.2(S)0.2(S) 0.2(S)0.5 0.2(S)5P10 0.5(5P10) | 20/20, 30/30, 30/30, 20/20 | 100 | 160 | 43 |
Dimension & outline drawing of LZZBJ9-24-220b-2s-4s — click image to zoom / view original.
LZZBJ9-24/220b/2s(4s) is the heavier of the two 24 kV frames: 43 kg, two or four cores, and 20 A to 3150 A primary. It exists because the 180b frame stops at 2500 A and at 20 VA; above that the winding package and the terminal block need the larger casting.
Rated output is 15/15 VA, 20/20 VA and 30/30 VA depending on the core pairing and ratio band, with accuracy 0.2(S)/0.2(S), 0.2(S)/0.5, 0.2(S)/5P10 or 0.5/5P10. Short-time thermal current is 150 times primary at 20–200 A and an absolute 100 kA with a 160 kA dynamic rating at 1000–3150 A.
For a 24 kV project, the choice between 180b and 220b is usually made by the maximum ratio and the metering burden, not by fault level alone. If the ratio is 2500 A or below and 20 VA is enough, the 36 kg 180b is the lighter option; otherwise specify the 220b.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-250b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-35A Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.