KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-35-250b-4s
LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZBJ9-35-250b-4s
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-35-250b-4s

LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-250b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer
  • multi-accuracy grades
  • reliable thermal and dynamic stability performance
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-35-250b-4s

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

35 kV four-core epoxy-cast CT, 20–3150 A, 0.2(5)/0.5/5P/5P with outputs up to 50 VA, 112 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-35-250b-4sFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium-voltage switchgear panels
  • Metering and protection applications up to 35kV
  • Revenue metering with 0.2S/0.5S accuracy
  • Protection schemes requiring 5P10/5P15/5P20 classes
  • Systems with short-circuit currents up to 31.5kA

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) applications
  • DC systems or non-sinusoidal waveforms
  • Ambient temperatures outside -5°C to +40°C
  • High-altitude installations above 1000m without derating

Topology & Wiring

Connect primary through the bushing. Secondary terminals: 1S1-1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the largest rated output in the LZZBJ9 range?

A: 50 VA on this model's first protection core, against 10–30 VA on the lighter 35 kV frames.

Q: What are the thermal ratings at 2000–3150 A?

A: They are listed as on request in the datasheet; the 800–1600 A band is rated 31.5 kA/4 s with 130 kA dynamic.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-35-250b-4s
6 cols · 9 rows

LZZBJ9-35/250b/4s Current Transformer

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSφ=0.8Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
200.2(5)/0.5/5P/5P30 30 50 40 304 110112
30-400.2(5)/0.5/5P/5P30 30 50 40 304 210112
500.2(5)/0.5/5P/5P30 30 50 40 3012 130112
750.2(5)/0.5/5P/5P30 30 50 40 3016 140112
100-1500.2(5)/0.5/5P/5P30 30 50 40 3025 163112
200-3000.2(5)/0.5/5P/5P30 30 50 40 3031.5 180112
400-6000.2(5)/0.5/5P/5P30 30 50 40 3031.5 280112
800-16000.2(5)/0.5/5P/5P30 30 50 40 3031.5 4130112
2000-31500.2(5)/0.5/5P/5P30 30 50 40 30[On Request][On Request]112
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-35-250b-4s — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-35-250b-4s

LZZBJ9-35/250b/4s is the 35 kV four-core model with the heaviest secondary burden in the family: 30 VA, 30 VA, 50 VA, 40 VA and 30 VA across its cores at the lower ratios. The 112 kg casting is what supports that winding volume at 35 kV insulation level, 40.5/95/185 kV.

It covers 20 A to 3150 A with accuracy 0.2(5)/0.5/5P/5P. Short-time thermal current is stated as 4 kA for 1 s at 20 A, rising through 12, 16, 25 and 31.5 kA to a 31.5 kA/4 s rating at 800–1600 A; dynamic ratings run from 10 kA to 130 kA. The last band, 2000–3150 A, is marked on request for thermal and dynamic figures.

This is the model to specify when the protection relays or metering equipment draw more than the 10–30 VA available on the lighter 35 kV frames. It is indoor only, and because of the mass it is normally installed with a lifting arrangement rather than hand-lifted into the panel.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-35A Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35A

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35A Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35D1

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35-G

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-G) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs