Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 40.5/95/185kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 20–3150A; accuracy-class rated outputs:10VA(0.2S/0.5S),30VA(0.5),30VA(5P10),20VA(5P15),15VA(5P20); short-time thermal current ranges 4–31.5kA, rated dynamic stable current ranges 10–130kA; product weight:78kg; ambient operating temperature -5℃~+40℃.
Indoor 35kV epoxy cast CT for MV switchgear metering and protection; rated insulation 40.5kV system, power-frequency withstand 95kV, lightning impulse 185kV peak.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZQB8-35-G | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Voltage | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 for metering, 2S1-2S2 for protection (if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: Rated insulation level is 40.5/95/185kV, meaning 40.5kV system voltage, 95kV power-frequency withstand, 185kV lightning impulse withstand.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only due to epoxy resin construction.
Q: What secondary currents are available?
A: Rated secondary current is 5A or 1A, as specified.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSΦ=0.8 (0.2/0.5S) | Accuracy class & rated output (VA) COSΦ=0.8 (0.5) | Accuracy class & rated output (VA) COSΦ=0.8 (5P10) | Accuracy class & rated output (VA) COSΦ=0.8 (5P15) | Accuracy class & rated output (VA) COSΦ=0.8 (5P20) | Short-time thermal current Ith (kA/S) (kA) | Short-time thermal current Ith (kA/S) (s) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 0.2(S)/0.5(S) | 10 | 30 | 30 | 20 | 15 | 4 | 1 | 10 | 78 |
| 30-40 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 4 | 2 | 10 | 78 |
| 50 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 12 | 1 | 30 | 78 |
| 75 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 16 | 1 | 40 | 78 |
| 100-150 | 0.2(S)/0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 25 | 1 | 63 | 78 |
| 200-300 | 0.2(S)/5P/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 1 | 80 | 78 |
| 400-600 | 0.5(S)/5P/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 2 | 80 | 78 |
| 800-1600 | [On Request] | 10 | 30 | 30 | 20 | 15 | 31.5 | 4 | 130 | 78 |
| 2000-3150 | [On Request] | 10 | 30 | 30 | 20 | 15 | [On Request] | [On Request] | [On Request] | 78 |

Dimension & outline drawing of LZZQB8-35-G — click image to zoom / view original.