Three-phase integrated current transformer for CGIS inflatable switchgear, multiple accuracy grades and abundant primary current specifications optional; secondary outgoing wires can be customized in length as required.
CGIS9815S is a 35kV dry epoxy resin current transformer for inflatable switchgear, suitable for metering and protection in RMU applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS9815S | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers, connect secondary terminals 1S1/1S2 for the main winding, and 2S1-2S2 for protection winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / IEEE C57.13 terminal conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: The primary voltage is 35kV.
Q: What insulation type is used?
A: Dry epoxy resin insulation.
Q: Can secondary wire length be customized?
A: Yes, secondary outgoing wires can be customized in length as required.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | burden (VA) | 100 h | 125 h | 150 h | 200 h | 250 h | 300 h | 400 h | 500 h | 600 h | 750 h |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2FS10 | 2.5 | — | — | — | 110 | 90 | 80 | 80 | 10 | 20 | 15 |
| 0.2FS10 | 5 | — | — | — | — | — | 120 | 90 | 30 | 25 | 20 |
| 0.2FS10 | 7.5 | — | — | — | — | — | — | 130 | 40 | 30 | 20 |
| 0.2FS10 | 10 | — | — | — | — | — | — | — | 55 | 35 | 25 |
| 0.2FS10 | 15 | — | — | — | — | — | — | — | 75 | 50 | 35 |
| 0.5FS10 | 2.5 | — | — | — | 40 | 25 | 15 | 10 | 10 | 15 | 15 |
| 0.5FS10 | 5 | — | — | — | 80 | 50 | 30 | 20 | 15 | 15 | 15 |
| 0.5FS10 | 7.5 | — | — | — | — | 70 | 45 | 25 | 20 | 20 | 15 |
| 0.5FS10 | 10 | — | — | — | — | 90 | 60 | 30 | 20 | 20 | 20 |
| 0.5FS10 | 15 | — | — | — | — | — | — | — | 60 | 50 | 25 |
| 0.5FS10 | 20 | — | — | — | — | — | — | — | — | — | — |
| 5P10 | 2.5 | 150 | 100 | 75 | 60 | 50 | 45 | 35 | 30 | 25 | 20 |
| 5P10 | 5 | — | — | 150 | 95 | 80 | 70 | 55 | 45 | 40 | 35 |
| 5P10 | 7.5 | — | — | — | 130 | 110 | 100 | 75 | 60 | 55 | 45 |
| 5P10 | 10 | — | — | — | — | — | 150 | 130 | 85 | 75 | 55 |
| 5P10 | 15 | — | — | — | — | — | — | — | 110 | 90 | 75 |
| 5P10 | 20 | — | — | — | — | — | — | — | 140 | 115 | 95 |
| 5P15 / 10P15 | 2.5 | 145 | 120 | 85 | 80 | 65 | 55 | 50 | 40 | 35 | — |
| 5P15 / 10P15 | 5 | — | — | 150 | 125 | 105 | 90 | 75 | 65 | 55 | — |
| 5P15 / 10P15 | 7.5 | — | — | — | — | 145 | 120 | 100 | 85 | 70 | — |
| 5P15 / 10P15 | 10 | — | — | — | — | — | 150 | 130 | 110 | 90 | — |
| 5P15 / 10P15 | 15 | — | — | — | — | — | — | — | 150 | 125 | — |
| 5P20 / 10P20 | 2.5 | — | — | 140 | 130 | 110 | 90 | 75 | 65 | 55 | — |
| 5P20 / 10P20 | 5 | — | — | — | — | — | — | 140 | 115 | 100 | 80 |
| 5P20 / 10P20 | 7.5 | — | — | — | — | — | — | — | — | — | 110 |
| 5P20 / 10P20 | 10 | — | — | — | — | — | — | — | — | — | 135 |
Dimension & outline drawing of CGIS9815S — click image to zoom / view original.
The CGIS9815S is a 35 kV dry epoxy resin current transformer built for three-phase integrated molded installation in inflatable switchgear, such as ring-main units and substation bays. Its compact molded body helps save panel space and simplifies switchgear room layout.
Available accuracy classes include 0.2FS10, 0.5SFS10, 0.5FS10, 5P10, 10P10, 5P15, 10P15, 5P20 and 10P20 at 50/60 Hz. For 0.2FS10 at 2.5 VA, the table lists 110 at 200 h, 90 at 250 h, 80 at 300 h and 80 at 400 h; for 0.5FS10 at 2.5 VA, 40 at 200 h, 25 at 250 h and 15 at 300 h. Insulation level and weight are [On Request]. The range suits metering and protection duties, with class and burden chosen against the fault level and connected relay or meter load.
Compliance evidence, including calibration certificates for revenue metering, is available [On Request]. Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Mount the unit per the outline drawing, earth the secondary at one point, and never open-circuit the secondary while energized. Ratio and accuracy-class combinations are customized; consult the factory for documentation packages and delivery.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.