KEMA Tested & ISO 9001/14001 Certified Manufacturing| Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

Mainland China

Mainland China中文

United States

United StatesEnglish

France

FranceFrançais

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B High Voltage Transformer Portal

PotentialTransformers.com is a leading international OEM & EPC supplier specializing in high-voltage potential transformers (3.3kV to 500kV), capacitive VTs (CVT), cast-resin dry transformers, and SF6 gas-insulated VTs for global power utilities, substations, and heavy industrials.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers (VT / PT)
  • Current Transformers (CT)
  • Power Step-Down Transformers

Engineering Tools

  • AI Spec & Selection Studio
  • Electromagnetic PT vs. Capacitive CVT: Selection Guide for 110kV–500kV Substations
  • Understanding IEC 61869-3: Accuracy Classes, Burdens, and Temperature Rise Limits
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCurrent TransformerLZZBJ9-12-198b-4s
LZZBJ9-12/198b/4s Indoor Single-phase Epoxy Cast Current Transformer 12kV
0.66kVLZZBJ9-12-198b-4s
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2): (0.5/1.0/3.0)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-12-198b-4s

LZZBJ9-12/198b/4s Indoor Single-phase Epoxy Cast Current Transformer 12kV

Indoor single-phase epoxy resin casting CT, compliant with GB/T20840.1/2 & IEC61869-1/2, insulation level 12/42/75kV, 50/60Hz, secondary current 5A/1A. Optional primary current ranges:20-200A、300-400A、500-600A、800-1000A、1200-1250A、1500-3150A; diversified accuracy combinations for metering and protection, independent withstand parameter matching, net weight 78kg, operating temperature -5℃~+40℃.

Key Engineering Advantages

  • 12kV insulation
  • epoxy casting
  • larger current coverage
  • weight 78kg
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-12-198b-4s

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Voltages:
Metering & Protection Class:0.5/1.0/3.0
Rated Output Burden:
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):
Partial Discharge Level:< 5 pC at 1.2 Un
Environmental Class:
Standards Conformance:IEC 61869 / GB/T 20840

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy cast CT for 12kV systems, suitable for metering and protection up to 3150A.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeLZZBJ9-12-198b-4sFactory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Voltage[On Request]Ratio check at rated frequency
Accuracy Class0.5/1.0/3.0Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • Revenue metering with accuracy class 0.5
  • Protection schemes requiring class 3.0
  • Primary currents from 20A to 3150A
  • 50/60Hz power systems

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) applications
  • High-voltage transmission systems above 12kV
  • DC systems
  • High altitude above 1000m without derating

Topology & Wiring

Connect primary through the bushing. Secondary terminals: 1S1 and 1S2 for metering winding; if protection winding exists, use 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 for terminal markings and safety clearances.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: The insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, and 75kV lightning impulse withstand.

Q: Can this CT be used for both metering and protection?

A: Yes, it offers accuracy classes 0.5, 1.0, and 3.0, allowing combinations for metering and protection.

Q: What is the weight and operating temperature range?

A: Net weight is 78kg, and operating temperature is -5°C to +40°C.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-12-198b-4s
6 cols · 6 rows

LZZBJ9-12/198b/4s Current Transformer — Technical Data

Rated primary current (A)Accuracy classCombinedAccuracy class & rated output (VA) COSφ=0.8Short-time thermal current (kA/S)Rated dynamic current (kA)Weight (kg)
2000.2(5)/0.5/5P/5P20 20 25 20 1515037582
3000.2(5)/0.5/5P/5P20 20 25 20 1531.58082
4000.2(5)/0.5/5P/5P20 20 25 20 1545112.582
500-6000.2(5)/0.5/5P/5P20 20 25 20 156313082
800-10000.2(5)/0.5/5P/5P30 30 40 30 208016082
1200-31500.2(5)/0.5/5P/5P30 30 40 30 2010016082