KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • AI Is Hungry for Power: How Many Instrument Transformers Does an AI Data Center Need?
  • From 110 kV to the GPU: CTs and PTs Across an AI Data Center Power Chain
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
High Voltage Equipment Directory

Voltage & Current Transformers

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

Category3
Voltage
Showing 382 Potential Transformer models
JDZX10-10-6R2G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6R2G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX10-10-6R2G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P),1.0/3P(6P), rated burden 20VA / 50VA / 60VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/3P(6P),0.5/3P(6P),1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 50VA / 60VA / 50VA
View Specs
LZZB(J)7-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZB-J7-35-Q

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZB(J)7-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZB-J7-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ-10-6G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 30VA / 60VA / 100VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 60VA / 100VA / 600VA
View Specs
LFZJ3-10 Indoor Single-phase Epoxy Resin Casting Current Transformer
10kV
Current Transformer50/60Hz

LFZJ3-10

Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:20-100A、150A、200-300A、400-800A、1000-1250A; accuracy combination 0.2S/5P、0.5S/5P with rated output 15VA/20VA/30VA. Short-time thermal current 150I₁ₙ, dynamic stable current 375I₁ₙ, net weight 23kg, operating ambient temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX10-10-6AJG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6AJG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX10-10-6AJG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 15VA / 30VA / 60VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA / 30VA / 60VA / 50VA
View Specs
LFZZB5-10 Indoor Single-phase Epoxy Resin Casting Current Transformer
10kV
Current Transformer50/60Hz

LFZZB5-10

Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current:20-50A、75A、100A、150A、200A、300A; accuracy combinations:0.2S/0.5、0.2S/10P、0.5/10P, rated output:0.2S10VA、0.5 15VA、10P15 20VA、10P20 25VA. Matched short-time thermal current & dynamic stable current for each gear, net weight 35kg, ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX10-10-6C1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6C1

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX10-10-6C1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P,0.5/3P,0.2/0.2/3P,0.2/0.5/3P, rated burden 10VA / 10VA / 100VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/3P,0.5/3P,0.2/0.2/3P,0.2/0.5/3P
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 10VA / 100VA / 100VA
View Specs
JDZX9-10-6BG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-6BG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-6BG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 15VA / 15VA / 100VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA / 15VA / 100VA / 50VA
View Specs
LZZB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZB8-35-Q

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZB8-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX11-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX11-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX11-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 20VA / 30VA / 250VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 30VA / 250VA / 100VA
View Specs
JDZF16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZF16-10-6W

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZF16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 25VA / 40VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5
Insulation TypeDry Epoxy Resin
Rated Burden25VA / 40VA
View Specs
LZZB9-35-198-CGIS Current Transformer for CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

LZZB9-35-198-CGIS

Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-35-198-CGIS is an indoor epoxy resin cast current transformer dedicated to 35kV CGIS gas-insulated (inflatable) switchgear cabinets. It is built for compact CGIS panels and offers excellent thermal and dynamic stability, with configurable current ratios and accuracy classes for metering and protection. Design and testing follow GB/T 20840.1, GB/T 20840.2, IEC 61869-1 and IEC 61869-2.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 20840.1
View Specs