Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
154 models
Indoor Bushing-Type High-Precision Current Transformer
Indoor single-phase circular bushing-type current transformer matched for 10kV ring main units, complying with GB/T20840.1/2 and IEC61869-1/2 standards.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1555 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 30VA / 60VA / 100VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
20kV/15kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Outdoor pole-mounted multi-winding power transformer, 20kV/15kV. 4000/5000VA capacity, epoxy resin cast. Provides reliable control power supply. Compliant with IEC 60076 and GB 1094 standards. Weather-resistant, suitable for outdoor installation.
Indoor Foot-Fixed High-Precision Current Transformer
LMZC-10 Indoor Foot-Fixed High-Precision Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P), rated burden 60VA(0.2),120VA(0.5),200VA(1.0),100VA(3P). Design: Dry Epoxy Resin, 50Hz/60Hz operation.
Indoor Open-Core Current Transformer for 10kV Ring Main Unit
LMZK-10 Indoor Open-Core Current Transformer for 10kV Ring Main Unit is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P), rated burden 20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P). Design: insulation level 0.72/3kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LDZB7-35 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1580 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2/0.5/6P(3P), rated burden 15VA / 20VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Cable-Fixed Self-Powered Current Transformer
LDZC-10PU Indoor Cable-Fixed Self-Powered Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),100VA(3P). Design: Dry Epoxy Resin, 50Hz/60Hz operation.
20kV/15kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Outdoor pole-mounted R-type bushing power transformer, 20kV/15kV. 4000/5000VA capacity, special R-type bushing design. Epoxy resin cast construction. Compliant with IEC 60076 standards. Weather-resistant, easy integration with switchgear.
20kV/15kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Outdoor pole-mounted single-phase power transformer for 20kV/15kV systems. 1000/2000/3000VA capacity options. Epoxy resin cast, weather-resistant design. Compliant with IEC 60076 standards. Provides control power for switchgear. Customizable voltage ratio.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1255 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2,0.5,1.0, rated burden 30VA / 60VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-35/250b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-250b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.