Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
154 models
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-150b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Two optional structures: 2s and 4s, primary current optional range 20-3150A. 2s model weight is 43kg with rated output 15-30VA at different accuracy grades; 4s model weight is 70kg with rated output 15-30VA at different accuracy grades; short-time thermal current ranges 31.5-100kA, rated dynamic stable current ranges 80-160kA; ambient operating temperature -5℃~+40℃.
CSJK-Φ80 to Φ200 Zero Sequence Current Transformer for Earth Fault Protection
Square epoxy cast zero sequence current transformer for 10kV systems. Available in Φ80 to Φ200 inner diameter specifications. Product performance complies with GB/T 20840.1, 2 and IEC 61869-1, 2. Primary main insulation guaranteed by cable, secondary winding tested. Secondary winding withstands 3kV power frequency voltage to ground for 1 minute. Square epoxy resin cast construction, compact design, easy installation. Used for ground fault protection in medium voltage systems.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Single-phase epoxy resin cast power transformer for 10kV/6kV pole-mounted switchgear. Provides reliable control power supply for circuit breakers. Compliant with IEC 60076 and GB 1094 standards. Low partial discharge, excellent moisture resistance. Customizable voltage ratio and capacity.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Single-phase epoxy resin cast power transformer for 10kV/6kV switchgear. Multi-winding design, 2000/3000VA capacity. Provides control and operation power supply. Compliant with IEC 60076 standards. Low partial discharge, long service life. Customizable voltage ratio.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Single-phase multi-winding power transformer for 10kV/6kV systems. 4000/5000VA capacity, epoxy resin cast. Provides reliable control power for switchgear. Compliant with IEC 60076 and GB 1094. Low PD, moisture resistant. Customizable specifications.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Outdoor pole-mounted single-phase power transformer, 10kV/6kV. 8000VA capacity, epoxy resin cast construction. Provides control power supply for pole-mounted switchgear. Compliant with IEC 60076 standards. Weather-resistant design, reliable outdoor performance.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Two optional structures: 2s and 4s; primary current optional range 20-2500A. For 2s type: rated output 10-20VA under different accuracy grades, weight 36kg; for 4s type: rated output 15-20VA under different accuracy grades, weight 50kg; short-time thermal current:31.5-100kA, rated dynamic stable current:80-160kA; ambient operating temperature -5℃~+40℃.
10kV Outdoor Epoxy Cast Current Transformer for Metering & Protection
Outdoor split-core current transformer, 10kV, model KXLW-10G. Install directly on cables or conductors without cutting. Hot-line installation possible with HV cables. Outdoor resin casting, UV resistant, -40°C to +40°C. With open-circuit protection, creepage >500mm. Compliant with IEC 61869 and GB/T 20840 standards.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:20-200A、300A、400-500A、600A、800A、1000-1500A、2000-3150A; accuracy combination 0.2S/10P15、0.5S/10P15, multi-grade rated output including 10VA/20VA/25VA. Matched thermal and dynamic withstand parameters for different specifications, net weight 23.5kg, operating ambient temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LDJ1-35 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.