Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
154 models
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000-3000A、4000-6000A; accuracy combinations including 0.2S/0.2S、0.2S/0.5S、0.2S/10P15/10P15、0.5S/10P15/10P15, rated output values 15VA/20VA/30VA corresponding to different accuracy grades, net weight 45kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 2500-5000A; multiple accuracy class combinations available with rated output ranging 20-30VA; product weight:60kg; ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A / 1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZB(J)7-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZB-J7-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:20-100A、150A、200-300A、400-800A、1000-1250A; accuracy combination 0.2S/5P、0.5S/5P with rated output 15VA/20VA/30VA. Short-time thermal current 150I₁ₙ, dynamic stable current 375I₁ₙ, net weight 23kg, operating ambient temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current:20-50A、75A、100A、150A、200A、300A; accuracy combinations:0.2S/0.5、0.2S/10P、0.5/10P, rated output:0.2S10VA、0.5 15VA、10P15 20VA、10P20 25VA. Matched short-time thermal current & dynamic stable current for each gear, net weight 35kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZB8-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-35-198-CGIS is an indoor epoxy resin cast current transformer dedicated to 35kV CGIS gas-insulated (inflatable) switchgear cabinets. It is built for compact CGIS panels and offers excellent thermal and dynamic stability, with configurable current ratios and accuracy classes for metering and protection. Design and testing follow GB/T 20840.1, GB/T 20840.2, IEC 61869-1 and IEC 61869-2.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
10kV Indoor Epoxy Cast Busbar-Type Single-Phase Current Transformer for Switchgear
10kV indoor busbar-type epoxy resin cast current transformer. Through-core design for easy installation on busbars. Rated insulation level 12/42/75kV, 50/60Hz, secondary current 5A or 1A. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting process, low partial discharge, reliable performance. Suitable for medium voltage switchgear, customizable ratio and accuracy.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ18-35G3-175-CGIS Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ21-12/148/2s 4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ21-12-148-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.