Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
154 models
Indoor Single-phase Epoxy Resin Casting Current Transformer
LDZJ9-20 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 5A/1A. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:20-100A、150A、200-300A、400-800A、1000-1250A; accuracy combination 0.2S/10P、0.5S/10P with rated output 10VA/15VA/20VA/25VA. Short-time thermal current 150I₁ₙ, dynamic stable current 375I₁ₙ, net weight 19kg, operating ambient temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:5-150A、200-300A、400-500A、600-1000A、1250-1500A; accuracy combination 0.2S/10P10、0.5/10P10 with rated output:0.2S class 10VA, 0.5 class 10VA, 10P10 class 15VA. Short-time thermal current 150I₁ₙ~80I₁ₙ and rated dynamic current 375I₁ₙ~160I₁ₙ corresponding to different current grades, net weight 21kg, operating ambient temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:5-150A、200-300A、400-500A、600-1000A、1250-1500A; accuracy combination 0.2S/10P10 & 0.5/10P10, rated output:0.2S 10VA, 0.5 10VA, 10P10 15VA. Corresponding short-time thermal current and dynamic stable current vary by current grade, net weight 21kg, ambient operating temperature -5℃~+40℃.
10kV Indoor Epoxy Cast Metering Current Transformer
10kV indoor epoxy resin cast current transformer specially designed for grid energy metering. Dual windings support 0.2S high-precision metering and protection. Rated output 10-15VA, primary current range 20A to 2000A. Compliant with IEC 61869 and GB/T 20840 standards. Ultra-low partial discharge design ensures metering accuracy. Vacuum epoxy casting process, moisture and salt-spray resistant. Suitable for State Grid metering applications, customizable ratio.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LMZB-20 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 5A/1A. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current:2500A、3000A、4000A、5000A; accuracy combinations include 0.2/5P20、0.5/5P10/5P20、0.2/5P10/5P20、0.2/5P20/5P20, corresponding rated output specifications such as 30/30VA,30/25/25VA etc., net weight 30kg, ambient operating temperature -5℃~+40℃.
Current Transformer
Indoor epoxy resin casting current transformer complying with GB/T20840.1, GB/T20840.2, IEC61869-1 and IEC61869-2 standards, rich primary current specifications and multi-type accuracy grades optional for different application scenarios.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000A、3000A、4000A、5000A、6000A; accuracy combinations include 0.2S/0.2S、0.2S/0.5S、0.2S/10P15、0.5S/10P15/10P15, corresponding rated output:20VA、30VA、40VA for different accuracy grades, net weight 50kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:400A、500A、600A、800A、1000A; accuracy combinations include 5P20/5P20/0.2S、5P20/5P20/0.5S; rated output:0.2S:15VA/20VA,0.5S:15VA/20VA,5P20:30VA, net weight 98kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1500A、2000A、3000A、4000A、5000A; accuracy combinations include 0.2S/0.2S、0.2S/0.5S、0.2S/5P20/5P20、0.5S/5P20/5P20, corresponding rated output values 20-60VA for different accuracy grades, net weight 45kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current:400A、500A、600A、800A、1000A、1200A、1250A; accuracy combinations:0.2S/0.5、0.2S/10P、0.5/10P, rated output:0.2S/0.5S 10VA、0.5 15VA、510P10 15VA、510P15 20/25VA, net weight 19kg, ambient operating temperature -5℃~+40℃.