Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
154 models
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:1000-1200A、1500A、2000-6000A; multiple accuracy combinations like 0.2S/0.5S、0.2S/10P15、10P15/10P15、0.5S/10P15, rated output values 15VA/20VA/30VA for different grades, net weight 30kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges: 300-400A、500-1000A、1200-1250A、2000-6000A; multiple accuracy combinations including 0.5S/0.5S、0.2S/10P10、0.5S/10P10、0.2S/10P15、0.5S/10P15、10P15/10P15, corresponding rated output 5VA-50VA. Weight varies by current range: 10–13.5kg 300-1000A, 24kg 1200-1250A, 36kg 2000-6000A; ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current ranges:20-150A、200A、300A、400A、500A、600-800A、1000-1250A; accuracy combinations:0.2S/510P10、0.5S/510P10、0.2S/0.5S, corresponding rated output:10VA for 0.2S,10VA for 0.5S,15VA for 510P10; short-time thermal current 16–64 kAS, rated dynamic stable current 40–160 kA, net weight 16kg, ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZQB8-35B Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZQB8-35-B) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2、IEC61869-1/2 and JB/T8510.1-2007 standards; rated insulation level 31.5/95/185kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 10-2000A; accuracy-class rated outputs range 10-60VA for grades 0.2S,0.5S,0.2,0.5,5P10,5P15,5P20; short-time thermal current ranges 15-100kA, rated dynamic stable current ranges 37.5-200kA; product weight:85kg; ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZQB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZQB8-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZQB8-35A Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
LKZB-Φ100 to Φ250 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker
Split-core zero sequence current transformer specially designed for 6kV-35kV indoor cable head outlets. Can be installed without power interruption - split into two halves and bolted together. Rated frequency 50Hz or 60Hz. Inner diameter range Φ100 to Φ250, suitable for various cable sizes. Compliant with IEC 61869 and GB/T 20840 standards. Hot-line installation capability saves downtime and maintenance cost. Epoxy resin cast construction, reliable performance.
Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV
LZJD-10G Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Low Voltage Current Transformer 0.66kV
LMK-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LA-10Q Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 5VA. Design: Dry Epoxy Resin, 50/60Hz operation.