KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCT
Product category

Current Transformer

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

154 models

Representative Models

LMZ3D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ3D-SKX1

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 600-800A, accuracy 0.2S/0.5S.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden10VA
View Specs
LMZ1D-SKX2 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ1D-SKX2

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast low-voltage current transformer of State Grid standard, primary rated current 100-150A, accuracy class 0.2S/0.5S, applied for metering in low-voltage power distribution systems.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden5VA
View Specs
SDH-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

SDH-0.66

Indoor Low Voltage Current Transformer 0.66kV

SDH-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LMZ4D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ4D-SKX1

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 800-1500A, accuracy 0.2S/0.5S.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden10VA
View Specs
BH-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

BH-0.66

Indoor Low Voltage Current Transformer 0.66kV

BH-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LN-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

LN-0.66

Indoor Low Voltage Current Transformer 0.66kV

LN-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LMZ1,2,3-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

LMZ1-2-3-0.66

Indoor Low Voltage Current Transformer 0.66kV

Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LMZJ1-0.5 Indoor Low Voltage Current Transformer 0.5kV
0.5kV
Current Transformer50/60Hz

LMZJ1-0.5

Indoor Low Voltage Current Transformer 0.5kV

Indoor low voltage current transformer, 0.5kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 60044-1 and GB/T 1208 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 60044-1 / GB/T 1208
View Specs
LMK8-0.66 Indoor Low Voltage Bury-plug Current Transformer 0.66kV
0.66kV
Current Transformer50/60Hz

LMK8-0.66

Indoor Low Voltage Bury-plug Current Transformer 0.66kV

Indoor low voltage bury-plug type current transformer, 0.66kV rated, epoxy resin casting type, for current measurement, control and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Bury-plug terminal design with connection pipes, easy and safe wiring. Compact size, transparent dust cover, clean and safe. Wide range of current ratios available. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LMZJ1-0.66W 0.66kV Outdoor Epoxy Cast Busbar-Type Current Transformer for Low Voltage Metering
0.66kV
Current Transformer50/60Hz

LMZJ1-0.66W

0.66kV Outdoor Epoxy Cast Busbar-Type Current Transformer for Low Voltage Metering

Outdoor busbar-type current transformer, rated voltage 0.66kV. Designed for low voltage outdoor distribution systems. Rated frequency 50Hz or 60Hz. Ambient temperature range -25°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Outdoor design with weather-resistant construction. Busbar through-core installation, easy to mount on low voltage busbars. Used for current measurement and protection in LV systems.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
LMZ2D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kV
Current Transformer50/60Hz

LMZ2D-SKX1

State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 200-600A, accuracy 0.2S/0.5S.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden5VA
View Specs
LFZZJ-12 Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LFZZJ-12

Indoor Single-phase Epoxy Resin Casting Current Transformer

LFZZJ-12 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 5VA. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2S/0.5S
Insulation TypeDry Epoxy Resin
Rated Burden5VA
View Specs
← Prev1…10111213Next →
Browse full catalogue