Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
154 models
Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV
LZZ-10Q Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Low Voltage Current Transformer 0.66kV Busbar Type
Indoor low voltage current transformer, 0.66kV rated, type III, busbar fixed installation, for current measurement and metering in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Large capacity, high accuracy, suitable for three-phase vertical busbar arrangement. Easy installation, wide range of current ratios available. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV
LZZB-10 Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 5P/10P. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Cast Current Transformer 12kV
Indoor single-phase epoxy resin casting CT, compliant with GB/T20840.1/2 & IEC61869-1/2, insulation level 12/42/75kV, 50/60Hz, secondary current 5A/1A. Optional primary current ranges:20-200A、300A、400A、500-600A、800-1000A、1200-3150A; multiple accuracy combinations of metering and protection grades, matched thermal/dynamic withstand parameters for each range, net weight 62kg, operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Cast Current Transformer 10kV
LZZB1-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Low Voltage Protection Current Transformer 0.66kV
Indoor low voltage protection current transformer, 0.66kV rated, epoxy resin casting type, for protection applications in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple protection accuracy classes 5P, 10P. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LFS-10G Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 10VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Low Voltage Split-core Current Transformer 0.66kV Open Type
Indoor low voltage split-core open type current transformer, 0.66kV rated, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Split-core design, can be directly installed on existing busbars without power interruption. Easy installation, wide range of current ratios available. Customizable ratios and specifications.
State Grid Standard 0.66kV Current Transformer
Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 75A, accuracy 0.2S/0.5S, for metering in low-voltage distribution systems.
Double Cable Current Transformer
Indoor epoxy resin casting double cable current transformer, compliant with GB/T20840.1, GB/T20840.2 and IEC61869-1, IEC61869-2 standards.
Indoor Single-phase Epoxy Cast Current Transformer 10kV
LZZB2-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Cast Current Transformer 10kV
LZZB3-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.